Samsung DV40J3000EW/A2 User Manual

Browse online or download User Manual for Unknown Samsung DV40J3000EW/A2. Samsung DV40J3000EW/A2 Manual de Usuario

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CLOTHES DRYER
SÈCHE-LINGE / SECADORA
Technical Information
Informations techniques / Información técnica
IMPORTANT SAFETY NOTICE – “For Technicians only”
This service data sheet is intended for use by persons having electrical, electronic, and mechanical experience and
knowledge at a level generally considered acceptable in the appliance repair trade. Any attempt to repair a major
appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible,
nor assume any liability for injury or damage of any kind arising from the use of this data sheet.
• Due to the possibility of personal injury or property damage, always contact an authorized technician for
servicing or repair of this unit.
• Refer to the service manual (DV40J3000E(G)*) for detailed installation, operating, testing, troubleshooting, and
disassembly instructions.
CONSIGNE DE SÉCURITÉ IMPORTANTE: réservée aux techniciens
Cette fiche de maintenance est destinée aux réparateurs disposant d'un niveau d'expérience et de connaissances
susants en matière d'électricité, d'électronique et de mécanique. Toute opération de réparation d'un gros
appareil électro-ménager est susceptible d'entraîner des blessures ou des dégâts matériels. Le fabricant ou le
vendeur ne peut pas être tenu responsable en cas de blessure ou de dégât matériel découlant de l'utilisation de
la présente fiche.
• En raison des risques de blessure ou de dommages matériels existants, demandez toujours à un technicien
qualifié d'eectuer les opérations d'entretien ou de réparation de l'appareil.
• Reportez-vous au manuel de réparation (DV40J3000E(G)*) pour connaître les consignes d'installation,
d'utilisation, de test, de dépannage et de démontage détaillées.
AVISO DE SEGURIDAD IMPORTANTE – “Solo para técnicos”
Esta hoja de datos de servicio está destinada a personas que tengan experiencia eléctrica, electrónica y
mecánica, así como conocimientos generales considerados aceptables en el servicio de reparación de aparatos
eléctricos. Cualquier intento de hacer reparaciones importantes podría causar lesiones físicas o daños materiales.
Ni el fabricante ni el vendedor se hacen responsables, ni asumen ninguna obligación legal por lesiones o daños de
cualquier tipo derivados del uso de esta hoja de datos.
• Dada la posibilidad de sufrir lesiones físicas o daños materiales, comuníquese siempre con un técnico
autorizado para realizar el mantenimiento de esta unidad o para repararla.
• Consulte el manual de servicio (DV40J3000E(G)*) para obtener instrucciones detalladas de instalación,
funcionamiento, prueba, solución de problemas y desensamble.
CAUTION / ATTENTION / PRECAUCIÓN
All safety information must be followed as provided in the service manual of DV40J3000E(G)*.
Toutes les consignes de sécurité figurant dans le manuel de réparation de DV40J3000E(G)* doivent être
respectées.
Toda la información de seguridad debe seguirse conforme al manual de servicio de DV40J3000E(G)*.
WARNING / AVERTISSEMENT / ADVERTENCIA
To avoid risk of electrical shock, personal injury, or death, disconnect the power to the dryer before servicing,
unless testing requires power.
CONTROL BOARD AND INLET VALVE ARE INTENTIONALLY NOT GROUNDED AND MAY PRESENT
A RISK OF ELECTRIC SHOCK ONLY DURING SERVICING. SERVICE PERSONNEL — DO NOT
CONTACT THIS PART WHILE APPLIANCE IS ENERGIZED.
Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf
si le test nécessite sa mise sous tension.
Para evitar riesgos de descarga eléctrica, lesiones o la muerte, antes de realizar el servicio desconecte el cable
de alimentación de la secadora a menos que la prueba requiera que esté conectada.
DC68-03171K
INFORMATION CODE ITEMS AND DIAGNOSTIC CODES
If an information code occurs, first all 8 LEDs turn ON and next the corresponding LED will be blinked while it
happens.
Information
code
Temp. Dry Time
Extra Low Low Medium High 20 min 40 min 60 min 80 min
DC
O
AC
O
BC2
O
TC2
O
DF
O
HC
O
9C1
O
FC
O O
INFORMATION
CODE DISPLAY
Meaning Action
TC
The thermistor resistance is
very low or high.
• Check for a clogged lint screen.
• Check if the vent system is restricted.
• Check the thermistor resistance.
DC
The dryer is running with the
door open.
• Close the door, and run the dryer again.
• Check if the door sensor unit is loose or short.
DF Incorrect door switch. • Check if the door sensor unit is loose or short.
BC2 Incorrect button state. • Check if the display PCB is loose or short.
FC Invalid power source frequency.
• Check if you are using regular power source
frequencies.
• Check the power frequency sensor circuit.
9C1
Electronic control problem
(Invalid Voltage).
• Check the PCB and wire harness.
• Check if power is supplied properly.
AC
Electronic control problem
(Invalid Communication).
• First check the PCB and wire harness.
• Replace the PCB if the problem persists.
HC
Invalid heating Temp in running
the dryer.
• Check the PCB and Thermistor.
TROUBLESHOOTING
Problem Action
Does not run • Make sure:
- all wires are connected properly to their corresponding terminals.
- the dryer is plugged in.
- the door switch is functional with the door closed. See Information code,
dF.
• Check the motor winding resistance: 2.88 ohms between pins #3 and 4,
3.5 ohms between pins #4 and 5
• Checkpoints: Rotary selector / Blown fuse or circuitbreaker / Controlboard
/ Belt cut-o switch / Drivingmotor
Motor runs but tumbler
does not turn
• Check if: the belt is loose, broken, and/or damaged.
the idler tension spring is too weak or stretched.
the idler pulley is jammed or stuck.
Runs a few minutes and
then stops
• Check if: lint is built up around the driving motor.
the voltage measured is too low.
the blower impeller is jammed in the blower housing.
the start switch of the drive motor is closed.
Problem Action
Blows fuses or trips
circuit breaker
• Is the belt connected properly?
• Do the rotor, stator, and the generator keep winding?
• Is the motor protector normal?
Otherwise, replace the PCB assembly.
Does not heat (motor
runs)
Open the heating element and check if:
• the Hi-Limit trips easily or is open.
• the regulating thermostat trips easily or is open.
• the membrane switch is open.
• the thermistor operates properly.
Blows fuses or
trips circuit breaker
(Gas models)
• During ignition, the dryer is designed to consume X amperage with the
burner turned on. If the dryer is using amperages above this, this indicates
the house wiring, fuse box, or circuit breaker is defective.
• Check if: the igniter harness is loose or short.
the drive motor is properly grounded.
Poor gas ignition
(Gas models)
A gas dryer featuring the heater unit is designed to flame within 45 seconds at
120 VAC. Ignition failure is indicated by one of three symptoms:
• The igniter does not glow.
• The igniter glows but does not ignite.
• The igniter ignites but goes out shortly.
The igniter does not
glow
If the igniter does not heat up, disconnect power and using an ohmmeter,
checkpoints:
• Flame sensor
• Igniter
• Booster coil
• Wiring
• Motor switch (neutral supply)
• Power connection (L1 supply)
The igniter starts
normally but fails to
ignite
If the igniter heats up but the main burner flame does not ignite, disconnect
power and using an ohmmeter, check the following:
• Secondary coil / Holding coil / Wire harness / Flame sensorifit’s closed
The dryer ignites but the
flame goes out shortly
• Check if: the radiant sensor is open prematurely.
the gas valve coil is open prematurely at higher temperatures.
• Checkpoints: Hi-Limit sensor / Venting system / Drum sealing
Dried clothes are
wrinkled / Rough
texture takes a longer
drying time
• The lint filter is not clean.
• The door of the exhaust hood damper is stuck closed.
• The exhaust system is too long or complicated, or has too many elbows
installed.
• The intake air is not sucient for the dryer.
• Incorrect tumbler speed or tumbler belt slipping.
• Check if the blower impeller is clogged with impurities.
• Check if the dryer is overloaded.
• Check the clothing label and select a proper cycle.
• Clothes are still wet after being washed in the washer.
Noise and/or vibrations • Thumping: check if the tumbler bae is loose, or if the rear tumbler rollers
are worn or misaligned.
• Ticking: check if the wire harness is loose, or if the blower wheel has
foreign objects caught in.
• Scraping: check if the front or rear bulkhead is out of position, or if the front
bearings of the tumbler are worn.
• Roaring: check if the blower wheel collides with the blower housing, or if
the motor bearings are worn.
• Popping or squealing: check for a sticky or frayed belt.
Component testing procedures
Component Electrical Testing (withohmmeter)
• Thermistor resistance 10K Ω @ 25 °C (77 °F)
• Thermostat 1 resistance < 1Ω
85 °C, 25A
Thermal Cut-O
THERMOSTAT1
THERMISTOR
• Thermostat 3 resistance < 1 Ω
- If resistance is infinite, replace thermostat3.
• Thermostat 2 resistance < 1 Ω
- If resistance is infinite, replace thermostat2.
• [SINGLE] Heater resistance 9.2~9.6 Ω (PIN 1&2)
- If resistance is infinite, replace heater.
• Measure resistance on the following terminal.
1. Door switch: O
- Terminal: “COM” - “NC” (1-3) < 1Ω
- Terminal: “COM” - “NO” (1-2): ∞ Ω
2. Door switch: On
- Terminal: “COM” - “NC” (1-3): ∞ Ω
- Terminal: “COM” - “NO” (1-2) < 1Ω
Door switch
125 V, 10A
• Belt Cut-o S/W
- Lever open: Resistance value < 1Ω
- Lever push: Resistance value: ∞ Ω
Belt Cut-O Switch 125 V, 16A
• Motor (Electronic & Gas) Contacts
Function 1M 2M 3M 4M 5M 6M
Start
Run
= Contact closed
Centrifugal Switch (Motor)
Switch shown in start position
• 3.05 Ω between Pin# 3 and 4
• 3.35 Ω between Pin# 4 and 5
Gas model
Radiant sensor (10RS)
• Resistance value < 1 Ω
• If resistance is infinite, replace radiant sensor.
120 V
Igniter (101D)
• Resistance value 40~400 Ω
• If resistance is infinite, replace igniter.
120 V, 4.5A
Gas valve (25M05A)
• Valve 1-2: Resistance value approx. 1365 Ω
• Valve 1-3: Resistance value approx. 560 Ω
• Valve 4-5: Resistance value approx. 1325 Ω
• If resistance is infinite, replace valve.
Thermostat (60T21 Hi-Limit) 230F-50F
• Resistance value < 1 Ω
• If resistance is infinite, replace thermostat.
250 V, 25A (60T2)
Main board layout
RY5
Motor Relay Switch
RY7
Heater Relay Switch
CN2
- RX
- TX
- SUB_RESET
- +5V
- GND
- +12V
Sensor bars & temperature sensor check
Sensor bars - Disconnect the harness and measure the
resistance between pink wire pin# 4 and orange wire pin# 5.
Approx. ∞ Ω without laundry
Approx. 190 Ω ± 10 % with wet clothes
Cycling thermistor 1 - Disconnect the harness and measure the
resistance between blue wire pin# 3 and red wire pin# 6.
Approx. 10 KΩ at 25 °C / 77 °F
ÉLÉMENTS CODE D’INFORMATION ET CODES DE DIAGNOSTIC
Si un code information se produit, les 8 LED s'allument d'abord puis la LED correspondante clignote pendant qu'il se
produit.
Code
d’information
Temp. Dry Time
Extra Low Low Medium High 20 min 40 min 60 min 80 min
DC
O
AC
O
BC2
O
TC2
O
DF
O
HC
O
9C1
O
FC
O O
Code
d’information
Signification Action
TC
La résistance de la thermistance
est très faible ou très élevée.
• Vérifiez si le filtre à peluches est bouché.
• Vérifiez si les capacités du système d'aération sont réduites.
• Vérifiez la résistance de la thermistance.
DC
Le sèche-linge fonctionne avec le
hublot ouvert.
• Fermez le hublot et allumez le sèche-linge.
• Vérifiez si le capteur du hublot est desserré ou court-circuité.
DF
Interrupteur du hublot incorrect. • Vérifiez si le capteur du hublot est desserré ou court-circuité.
BC2
État du bouton incorrect.
• Vérifiez si le circuit principal de la carte de circuit imprimé de
l'achage est desserré ou court-circuité.
FC
Fréquence de source d'alimentation
non valide.
• Vérifiez si vous utilisez les fréquences d'alimentation correctes.
• Vérifiez le circuit du capteur de fréquence d'alimentation.
9C1
Problème électronique (Tension
invalide).
• Vérifiez la carte de circuit imprimé et le faisceau électrique.
• Vérifiez que l'alimentation est correcte.
AC
Problème électronique
(Communication invalide).
• Vérifiez tout d'abord la carte de circuit imprimé et le faisceau
électrique.
• Remplacez la carte de circuit imprimé si le problème persiste.
HC
Température de chauage non
valide lors du fonctionnement du
sèche-linge.
• Vérifier le PCB et la thermistance.
DÉPANNAGE
Problème Action
Ne fonctionne pas • Assurez-vous que:
- tous les câbles sont connectés correctement à leurs bornes correspondantes.
- le sèche-linge est branché.
- l'interrupteur du hublot fonctionne avec le hublot fermé. Voir le code d’information, dF.
• Vérifiez la résistance de la bobine du moteur: 2,88ohms entre les broches #3 et 4,
3,5ohms entre les broches #4 et 5
• Contrôles à eectuer: Molette / Fusible grillé ou disjoncteur déclenché / Panneau de
commande / Interrupteur de désactivation de la courroie / Moteur
d'entraînement
Le moteur fonctionne mais le
tambour ne tourne pas
• Vérifiez si: la courroie est desserrée, rompue, et/ou endommagée.
le ressort de tension du galet est trop faible ou étiré.
le galet-tendeur est bloqué ou grippé.
Fonctionne quelques minutes
puis s'arrête
• Vérifiez si: des peluches se sont formées autour du moteur d'entraînement.
la tension mesurée est trop basse.
la turbine du ventilateur est bloquée dans le logement du ventilateur..
l'interrupteur de démarrage du moteur d'entraînement est fermé.
Fait griller les fusibles ou
déclenche le disjoncteur
• La courroie est-elle correctement fixée?
• Le rotor, le stator et la génératrice continuent-ils d'enrouler?
• La protection du moteur est-elle normale?
Dans le cas contraire, remplacer la carte de circuit imprimé.
Ne chaue pas
(le moteur tourne)
Ouvrez l'élément chauant et vérifiez si :
• le régulateur se déclenche facilement ou est coupé.
• le thermostat de régulation se déclenche facilement ou est coupé.
• le commutateur de membrane est coupé.
• la thermistance fonctionne correctement.
Problème Action
Fait griller les fusibles ou
déclenche le disjoncteur
(modèles à gaz)
• Lors de l'allumage, le sèche-linge consomme X A avec le brûleur allumé. Si la
consommation du sèche-linge est supérieure à ces valeurs, cela signifie que le système
électrique du domicile, la boîte de fusibles ou le disjoncteur est défectueux.
• Vérifiez si: le faisceau électrique de l'allumeur est mal connecté ou court-circuité à la base.
le moteur d'entraînement est correctement mis à la terre.
Mauvais allumage
(modèles à gaz)
L'allumeur d'un sèche-linge au gaz doté d'une résistance chauante doit s'allumer dans les
45 secondes à 120 V CA. Dans le cas contraire, cela est indiqué par l'un des trois symptômes
suivants :
• L'allumeur ne s'allume pas.
• L'allumeur s'allume mais ne s'enflamme pas.
• L'allumeur s'enflamme mais s'éteint rapidement.
L'allumeur ne s'allume pas. Si l'allumeur ne chaue pas, coupez l'alimentation et à l'aide d'un ohmmètre, vérifiez les
points suivants :
• Capteur de flamme
• Allumeur
• Survolteur
• Câblage
• Commutateur de moteur (courant neutre)
• Connexion à l'alimentation (courant L1)
L'allumeur démarre
normalement mais ne
s'enflamme pas
Si l'allumeur chaue mais le brûleur principal ne s'enflamme pas, coupez l'alimentation et à
l'aide d'un ohmmètre, vérifiez les points suivants :
• Bobine secondaire / Bobine de maintien / Faisceau électrique / Capteur de flamme s'il
est fermé
Le sèche-linge s'allume
mais la flamme s'éteint
rapidement
• Vérifiez si: le capteur radiant est ouvert prématurément.
le bobinage d'une vanne de gaz est ouvert prématurément lorsqu'il est soumis
à des températures plus élevées.
• Contrôles à eectuer: Capteur du régulateur / Système d'aération / Joints du tambour
Le linge sec est froissé /
Le séchage du linge à texture
rêche est plus long
• Le filtre à peluches est sale.
• Le registre du système d'aération est bloqué.
• Le système d'évacuation est trop long ou compliqué ou a trop de coudes installés.
• La prise d'air n'est pas susante pour le sèche-linge.
• La vitesse du tambour est incorrecte ou la courroie du tambour glisse.
• Vérifiez si la turbine du ventilateur est bloqué par des impuretés.
• Vérifiez si le sèche-linge est surchargé.
• Contrôlez l'étiquette du vêtement et sélectionnez un programme approprié.
• Les vêtements sont toujours mouillés après avoir été lavés dans le lave-linge.
Bruit et/ou vibrations • Bruit sourd: vérifiez si les battants du tambour sont desserrés, si le ou les rouleaux arrière
du tambour sont usés ou mal alignés.
• Cliquetis: vérifiez si les fils couplés ne sont pas mal connectés ou si aucun objet n'est pris
dans la roue du ventilateur.
• Raclement: vérifiez si la rondelle en feutre du bloc avant ou arrière ne s'est pas déplacée
ou si les roulements avant du tambour ne sont pas usés.
• Grondement: vérifiez si la roue du ventilateur frotte contre le logement du ventilateur ou si
les roulements du moteur sont usés.
• Claquement ou grincement: vérifiez que la courroie n'est pas collante ou elochée.
120V, 60Hz, 120A
Français canadien Français canadien Français canadienEnglish English English English
DV3000J_DV40J3000EW_TECH MANUAL_DC68-03171K.indd 1-8 2014/12/31 15:36:33
Page view 0
1 2

Summary of Contents

Page 1 - CLOTHES DRYER

CLOTHES DRYERSÈCHE-LINGE / SECADORATechnical InformationInformations techniques / Información técnicaIMPORTANT SAFETY NOTICE – “For Technicians only”T

Page 2 - SOLUCIÓN DE PROBLEMAS

WIRING DIAGRAM (SCHÉMA DE CâBLAGE / DIAGRAMA DEL CABLEADO)Procédures de test des composantsTest des composants électriques (avec ohmmètre)• Résistanc

Comments to this Manuals

No comments