10Basic operation is an operation mode that can be selected by pressing the Mode button. AutoIn Auto mode, the air conditioner will automatically set
11ENGLISHPress the button to turn on the air conditioner.Press the button to set the operating mode.• EachtimeyoupresstheMode button, the mo
12Adjusting the air ow directionAir ow can be directed to your desired position.Turbo function will be helpful to cool your room quickly and eectiv
ENGLISH13 modeFor a comfortable sleep, the air conditioner will operate it Fall asleep Sound sleep Wake up from mode.1. Press the button on t
14Setting the On/O timerYou can set the air conditioner to turn on/o automatically at desired time. Setting On timer while the air conditioner is o
ENGLISH15Combining On Timer and O TimerIf the air conditioner is on If the air conditioner is oPreset time on On timer is longer than O timerEx)On
16Using the Auto Clean functionAuto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit. Your indoor u
ENGLISH17Cleaning the air conditionerCleaning the indoor unitCleaning the outdoor unit heat exchangerOpening the panel Wipe the surface of the unit
18Cleaning the air conditionerRemoving the Air lterGrab the handle and lift it up. Then, pull the Air lter towards you and slide it down. Air lterC
ENGLISH19Maintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it
2This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (20
20TroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTION
21ENGLISHPROBLEM SOLUTIONError is indicated. • When an indoor unit indicator blinks, contact the nearest service center.Noise is generated. • Depe
22Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.•Alwaysdisconnecttheaircondi
ENGLISH23Installing the unitIMPORTANT:Wheninstallingtheunit,alwaysremembertoconnectrsttherefrigeranttubes,thentheelectricallines. A
24Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rainWhere neighbors a
25ENGLISHSpace Requirements for Outdoor UnitWhen installing 1 outdoor unitWhen installing more than 1 outdoor unit300 or more When the air outlet is
26Choosing the installation location(Unit:mm) When the upper part of the outdoor unit and the air outlet is opposite the wall When the walls are
ENGLISH27• Makesuretodrillonlyonehole after choosing the direction of the pipe.Fixing the installation plateThe following connection accessori
28Wall<20mmPlastic AnchorFixing the installation plate2. Fix the indoor unit.If you x the indoor unit on a wall (1) Fix the installation plate
ENGLISH292 . Open the front grille.3 . Remove the screw securing the connector cover.4 . Pass the assembly cable through the rear of the indoor uni
ENGLISH3Safety precautionsBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and ecientl
30Installing and connecting the assembly pipe of the indoor unit1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit u
ENGLISH31Purging the indoor unit1. Unscrew the caps at the end of each pipe. All inert gas exhausts from the indoor unit. 1. Make sure that yo
32Cutting or extending the pipeOuter Diameter Torque (kgf•cm)ø6.35 mm 140~170ø9.52 mm 250~280ø12.70 mm 380~420ø15.88 mm 440~480ø19.05 mm 990~1210ø22.2
ENGLISH33• Thehosewillbexedpermanentlyintopositionafternishingtheinstallationandthegasleaktest;refertopage37~38 for further de
34Installing and connecting the drain hose of the outdoor unitFrameGroundEstimated snow fallSnow-proof hoodBottom surface of outdoor unitDrain hoseDra
ENGLISH353. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture.4. Open the valve of t
36Purging the connected pipesRefrigerant type GWP valueR410A 1975 GWP=Global Warming PotentialIndoor unitOutdoor unit= ( ) kg= ( ) kg+= ( ) kg
ENGLISH37Performing the gas leak testsCDABMake sure to check for gas leaks before completing the installation process (connecting the assembly pipe an
38Fixing the indoor unit in placeInsulationPipes'X' mmRubber leg'Y' mmPerform the following work on the area where gas leak test w
ENGLISH39Final Check and Trial OperationTo complete the installation, perform the following checks and tests to ensure that the air conditioner operat
4Safety precautionsFOR POWER SUPPLYWARNINGRemove all foreign substances such as dust or water from the power plug terminals and contact points using a
40How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1.
ENGLISH41Memo
QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT AUSTRIA 0810 - SAMSUNG (7267864, € 0.07/min) www.samsung.comBELGIUM 02-201-24-18www.samsung
AQ09T SeriesAQ12T SeriesAQ18T SeriesAQ24T SeriesAQ09U SeriesAQ12U SeriesAQ18U SeriesAQ24U SeriesAir Conditioneruser & installation
5ENGLISHFOR USINGWARNINGDo not place an object near the outdoor unit that allows children to climb onto the machine. This may result in children ser
6Operation rangesThe table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for eci
ENGLISH7Main partsDisplay indicatorTimer/Auto clean indicatorOperation indicatorPower buttonRemote controller receiverYour air conditioner may sligh
8Checking the remote controllerRemote controller buttons• Pointtheremotecontrollertowardstheremotecontrollerreceiveroftheindoorunit.• W
9ENGLISHRemote controller display• Thesignalmaynotbereceivedwellofelectroniclightingstyleuorescentlampssuchasinverteruorescentlam