8-7. LOAD OPERATION circuit part
When ÒHighÓ signal is supplied to INPUT of IC03 (ULN2003A) at MICOM PIN NO #22 (P15), IC comes to be
turned on. At this time, if V12 (DC 12V) supplied to the lower COIL of COMP RELAY runs into GROUND
through OUTPUT of IC03, magnetic field will occur at CORE and then make contact point ON. This approves
220 V to COMP LOAD to make COMP ON and, if MICOM PIN NO #22 becomes ÒLowÓ state, IC comes to be
TURN OFF state to make current not running to COMP RELAY COIL, to make RELAY contact point OFF state,
and then, finally to stop COMP.
1. Explanation of co-operation of COMP and F, R-Defroster HEATER
RED
COMP load
F-Defroster Heater
R-Defroster Heater
GRY
R-Defroster
Heater
F-Defroster
Heater
RED-RED
BLU-BLUE
ORG-ORANGE
BRN-BROWN
PNK-PINK
GRY-GRAY
WHT-WHITE
YEL-YELLOW
BLK-BLACK
PRP-PURPLE
W/BLK-
WHITE/BLACK
S/BLU-
SKY BLUE
REFERRENCE
WHT
PRP
BRN
GRY
YEL
RED
W-BLK
BLU
ORG
WHT
RED
L-BLU
BLK
F-Defroster Heater
F-ROOM LAMP
Circulation Fan
DISPENSER HEATER
DISPENSER LIGHT
SOLENOID-VALVE
Circulation Fan
HOME BAR HEATER
Compressor
R-Defroster Heater
COMP-FAN for basic model
GRN
RED
RED
GRY
RED
RED
RED
RED
GRY
BLK
PRP
Temperature Fuse
Temperature Fuse
RED
RED
ORG
BLU
28