Air conditionerUser & Installation manualAJ***NB1DEH ࡛ Thank you for purchasing this Samsung air conditioner. ࡛ Before operating this unit, pleas
10EnglishSafety InformationSafety InformationSafety Information FOR CLEANING WARNING Do not clean the appliance by spraying water directly onto it.
11EnglishAt a GlanceIndoor Unit OverviewMain partsThe indoor unit and its display may look slightly different from the illustration shown below, depen
12EnglishAt a GlancePower Smart FeaturesOperating temperature and humidityWhen using the air conditioner follow the operating temperature and humidity
13EnglishCleaning and MaintenanceCleaning and MaintainingCleaning the indoor unit exterior Wipe the surface of the indoor unit with a tepid damp cloth
14EnglishCleaning and MaintainingCleaning and MaintenanceCleaning the air filter CAUTION࡛ Before cleaning the indoor unit, be sure to turn off the a
15EnglishCleaning and Maintenance2 Cleaning the air filterClean the air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse
16EnglishCleaning and MaintainingCleaning and Maintenance4 Resetting the air filter (Wired remote control is an optional item.)After cleaning and rea
17EnglishCleaning and MaintenancePeriodical maintenanceUnit Maintenance item IntervalRequires qualified techniciansIndoor unitClean the air filter. At
18EnglishCleaning and MaintainingCleaning and MaintenanceTroubleshootingRefer to the following chart if the air conditioner operates abnormally. This
19EnglishCleaning and MaintenanceProblem SolutionThe air conditioner is not turned on or off immediately with the wired remote control.࡛ Check whethe
2English ContentsSafety Information 4Safety Information 4At a Glance 11Indoor Unit Overview 11Main partsPower Smart Features 12Operating temper
20EnglishCleaning and MaintainingCleaning and MaintenanceProblem SolutionThe air is not cool or warm enough.࡛ Close the windows and doors to maximize
21EnglishCleaning and MaintenanceInformation about refrigerantImportant information: regulation regarding the refrigerant usedThis product contains fl
22English Safety Information on InstallationSafety Information on Installation WARNING࡛ Hazards or unsafe practices that may result in severe perso
23EnglishSafety Information on Installation࡛ Do not use the air conditioner in environments with hazardous substances or close to equipment that rele
24EnglishInstallation Procedure Installation ProcedureInstallation Procedure Step 1 Checking and preparing accessoriesThe following accessories are s
25EnglishInstallation ProcedureIndoor unit dimensions(Unit: mm)4101453422465077970801301795001198Ceiling1150 (Ceiling opening dimension)249(Space of s
26EnglishInstallation Procedure Installation ProcedureSpacing requirementsA: 1500 mm or moreAAAA CAUTION࡛ The indoor unit must be installed accordin
27EnglishInstallation Procedure3 Install the suspension bolts, depending on the ceiling type.Ceiling support CAUTION࡛ Make sure that the ceiling is
28EnglishInstallation Procedure Installation ProcedureStep 5 Purging inert gas from the indoor unitThe indoor unit comes with nitrogen gas (inert gas
29EnglishInstallation ProcedureStep 7 Connecting the assembly pipes to the refrigerant pipesThere are two refrigerant pipes of different diameters :࡛
3EnglishCorrect Disposal of This Product (Waste Electrical & Electronic Equipment)(Applicable in countries with separate collection systems)This m
30EnglishInstallation Procedure Installation ProcedureStep 8 Performing the gas leak testTo identify potential gas leaks on the indoor unit, inspect
31EnglishInstallation Procedure5 Select the insulation of the refrigerant pipe.࡛ Insulate the gas side and liquid side pipe, noting the insulation t
32EnglishInstallation Procedure Installation Procedure5 Push the drain hose up to insulation when connecting the drain hose to drain socket.Metal cla
33EnglishInstallation Procedure࡛ Max. allowable bending angleđɇуߥߢઘIndoor unit NOTE࡛ If a concentrated drain pipe is installed, refer to the figu
34EnglishInstallation Procedure Installation Procedure CAUTION࡛ Only in the Cool mode, you can check the correct operation of the drain pump.When th
35EnglishInstallation ProcedureIndoor power supplyPower supply Max/Min(V) Indoor power cable220 to 240V, 50 Hz±10%1.5 to 2.5 mm², 3 wiresCommunication
36EnglishInstallation Procedure Installation Procedure CAUTION࡛ For information about the power cable specifications for indoor and outdoor units, r
37EnglishInstallation Procedure WARNING࡛ In case of extending the electric wire, please DO NOT use a round-shaped Pressing socket. – Incomplete wire
38EnglishInstallation Procedure Installation ProcedureTake the steps presented in the following table:Steps Remote control display1 Set the SEG2 and
39EnglishInstallation ProcedureSteps Remote control displayWhen you press the (Low Fan) or (High Fan) button, values appear in the following order
4EnglishSafety InformationSafety InformationSafety Information Before using your new air conditioner, please read this manual thoroughly to ensure tha
40EnglishInstallation Procedure Installation ProcedureSteps Remote control display10 Press the (Mode) button. Auto and Off appear on the remote cont
41EnglishInstallation ProcedureSteps Remote control displayb Set the SEG20 value by pressing the (High Fan) button repeatedly until the value you w
42EnglishInstallation Procedure Installation Procedure3 Check whether the option values that you have set are correct by pressing the (Mode) button
43EnglishInstallation ProcedureSetting an indoor unit address (MAIN/RMC)࡛ The indoor unit address are set to 0A0000-100000-200000-300000 by default.O
44EnglishInstallation Procedure Installation ProcedureSetting an indoor unit installation option (suitable for the condition of each installation loca
45EnglishInstallation ProcedureInstallation option (Detailed)Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXXOption SEG1 SEG2 SEG3 SEG4 SEG5 SEG6Explanation P
46EnglishInstallation Procedure Installation ProcedureOption SEG19 SEG20(*2) SEG21 SEG22 SEG23 SEG24Explanation PageIndividual control with remote con
47EnglishInstallation ProcedureChanging the addresses and options individuallyWhen you want to change the value of a specific option, refer to the fol
48EnglishAppendixAppendixTroubleshootingDetection of errors࡛ If an error occurs during the operation, an LED flickers and the operation is stopped ex
49EnglishAppendixAbnormal conditionError codeIndoor unit display indicationsIce BlueYellow GreenCOND mid sensor is detached E241XXRefrigerant leakage
5EnglishSafety Information The installation of this appliance must be performed by a qualified technician or service company.࡛ Failing to do so may
50EnglishMemoAppendix
51EnglishAppendix
QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT AUSTRALIA 1300 362 603 (Other) www.samsung.com/au/supportDB68-07854A-00
6EnglishSafety InformationSafety InformationSafety Information When installing the outdoor unit, make sure to connect the drain hose so that drainin
7EnglishSafety Information In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do
8EnglishSafety InformationSafety InformationSafety Information Do not insert your fingers or foreign substances into the air inlet/outlet of the air
9EnglishSafety Information Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted cigarettes, dishes, chem