Samsung AQV09PSBX User Manual

Browse online or download User Manual for Split-system air conditioners Samsung AQV09PSBX. Samsung Mural - AQV12PSBN manual de utilizador

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 2 - Contents

10Basic operation is an operation mode that can be selected by pressing the Mode button. AutoIn Auto mode, the air conditioner will automatically set

Page 3

11ENGLISHPress the button to turn on the air conditioner.Press the button to set the operating mode.• EachtimeyoupresstheMode button, the mod

Page 4

12Adjusting the air ow directionAir ow can be directed to your desired position.Turbo function will be helpful to cool your room quickly and eectiv

Page 5 - FOR CLEANING

13ENGLISH modeFor a comfortable sleep, the air conditioner will operate it Fall asleep  Sound sleep  Wake up from mode.1. Press the button on th

Page 6 - Checking before use

14Setting the On/O timerYou can set the air conditioner to turn on/o automatically at desired time. Setting On timer while the air conditioner is o

Page 7 - Main parts

15ENGLISHCombining On Timer and O TimerIf the air conditioner is on If the air conditioner is oPreset time on On timer is longer than O timerEx)On

Page 8 - Remote controller buttons

16Auto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit. Your indoor unit evaporates the moisture i

Page 9 - Remote controller display

17ENGLISHCleaning the air conditionerCleaning the indoor unitCleaning the outdoor unit heat exchangerOpening the panel Wipe the surface of the unit

Page 10 - Basic function

18Cleaning the air conditionerRemoving the Air lterGrab the handle and lift it up. Then, pull the Air lter towards you and slide it down. Air lterC

Page 11

19ENGLISHMaintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it

Page 12 - Using the Turbo function

2This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (20

Page 13

20TroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTION

Page 14 - Setting the On/O timer

21ENGLISHPROBLEM SOLUTIONError is indicated. • When an indoor unit indicator blinks, contact the nearest service center.Noise is generated. • Depe

Page 15

22Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.•Alwaysdisconnecttheaircondi

Page 16 - Using the Auto Clean function

23ENGLISHInstalling the unitIMPORTANT:Wheninstallingtheunit,alwaysremembertoconnectrsttherefrigeranttubes,thentheelectricallines. A

Page 17 - Cleaning the air conditioner

24Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rainWhere neighbors a

Page 18

25ENGLISHSpace Requirements for Outdoor UnitWhen installing 1 outdoor unitWhen installing more than 1 outdoor unit300 or more When the air outlet is

Page 19 - Periodical checks

26Choosing the installation location(Unit:mm) When the upper part of the outdoor unit and the air outlet is opposite the wall When the walls are

Page 20 - Troubleshooting

27ENGLISH• Makesuretodrillonlyonehole after choosing the direction of the pipe.Fixing the installation plateThe following connection accessori

Page 21

28Wall<20mmPlastic AnchorFixing the installation plate2. Fix the indoor unit.If you x the indoor unit on a wall (1) Fix the installation plate

Page 22 - Safety precautions

29ENGLISH When you install the unit, make rst refrigerant connections and then electrical connections. Connect the air conditioner to grounding sys

Page 23 - Indoor unit

3ENGLISHSafety precautionsBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and ecientl

Page 24 - Outdoor Unit

30Connecting the assembly cable• Endofthewiremustbecircular.• Afterconnectingthecables,makesureterminalnumbersontheindoor/outdoorun

Page 25

31ENGLISHPurging the indoor unit4. Cut o the remaining foam insulation. 5. If necessary, bend the pipe to t along the bottom of the indoor unit.

Page 26 - Accessories

32Cutting or extending the pipe1. Make sure that you have all the required tools (pipe cutter, reamer, aring tool and pipe holder).2. If you want t

Page 27 - Fixing the installation plate

33ENGLISHInstalling and connecting the drain hose of the indoor unitWallIndoor unitDrain hoseThe drain hose must NOT slant upwards. The end of the dr

Page 28 - Connecting the assembly cable

34Installing and connecting the drain hose of the indoor unit• Makesuretheindoorunitisinuprightpositionwhenyoupourwatertocheckforlea

Page 29

35AAENGLISHInstalling and connecting the drain hose of the outdoor unitFrameGroundEstimated snow fallSnow-proof hoodBottom surface of outdoor unitDrai

Page 30

36Purging the connected pipes3. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture.4.

Page 31 - Cutting or extending the pipe

37ENGLISHRefrigerant type GWP valueR410A 1975 GWP=Global Warming PotentialIndoor unitOutdoor unit= ( ) kg= ( ) kg+= ( ) kgContains uorinated

Page 32

38AAPerforming the gas leak testsCDABMake sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hos

Page 33 - Drain hose installation

39AAENGLISHFixing the indoor unit in placeInsulationPipes'X' mmRubber leg'Y' mmPerform the following work on the area where gas le

Page 34 - Drain pan outlet

4Safety precautionsFOR POWER SUPPLYWARNINGRemove all foreign substances such as dust or water from the power plug terminals and contact points using a

Page 35 - Purging the connected pipes

40AAFinal Check and Trial OperationTo complete the installation, perform the following checks and tests to ensure that the air conditioner operates co

Page 36

41AAENGLISH Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1. As shown in the gure, peel o

Page 37

42AASub PCB installation(optional)(Wried remote controller, central remote controller etc.)1. Turn the power o and take o the front panel of the in

Page 39

"EEE Yönetmeliğine Uygundur" "This EEE is compliant with RoHS"QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT AUSTRIA081

Page 40

AQV07P SeriesAQV09P SeriesAQV12P SeriesAQV18P SeriesAQV24P SeriesAir Conditioneruser & installation manualimagine the possibilitiesThank you

Page 41

5ENGLISHFOR USINGWARNINGDo not place an object near the outdoor unit that allows children to climb onto the machine. This may result in children ser

Page 42

6Operation rangesThe table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for eci

Page 43

7ENGLISHMain partsDisplay indicatorTimer/Auto clean indicatorOperation indicatorPower buttonRemote controller receiverYour air conditioner may sligh

Page 44 - QUESTIONS OR COMMENTS?

8Checking the remote controllerRemote controller buttons• Pointtheremotecontrollertowardstheremotecontrollerreceiveroftheindoorunit.• W

Page 45 - Air Conditioner

9ENGLISHRemote controller display• Thesignalmaynotbereceivedwellofelectroniclightingstyleuorescentlampssuchasinverteruorescentlam

Comments to this Manuals

No comments