Page 1

AQV09K&Y@@_Jungfrau_IBIM_E_32437A.indd 1 2011-1-17 17:06:13

Page 2 - Contents

10Basic operation is an operation mode that can be selected by pressing the Mode button. AutoIn Auto mode, the air conditioner will automatically set

Page 3

11ENGLISHPress the button to turn on the air conditioner.Press the button to set the operating mode.• EachtimeyoupresstheMode button, the mod

Page 4

12Adjusting the air  ow directionAir  ow can be directed to your desired position.Turbo function will be helpful to cool your room quickly and e ec

Page 5 - FOR CLEANING

ENGLISH13 modeBefore using good' sleep mode, set the current time.(For setting current time, refer to the page 14.)For a comfortable sleep, the a

Page 6 - Checking before use

14Setting the On/O timerYou can set the air conditioner to turn on/o automatically at desired time. Setting On timer while the air conditioner is

Page 7 - Main parts

ENGLISH15• OntimerandOtimersettingtimeshouldbedierentfromeachother.• PresstheSet/Cancel button on the remote controller while ti

Page 8 - Remote controller buttons

16Using the Smart Saver functionThis function will set the temperature range limit to help you save energy while the air conditioner is operating in C

Page 9 - Remote controller display

ENGLISH17Using the Auto Clean functionAuto clean function will prevent mold from growing by eliminating the moisture inside of the indoor unit. Your i

Page 10 - Basic function

18AAUsing the Quiet functionYou can reduce the noise generated from an indoor unit. Press the Quiet button on the remote controller while the air con

Page 11

ENGLISH19Cleaning the air conditionerCleaning the indoor unitCleaning the outdoor unit heat exchangerOpening the panel Wipe the surface of the unit

Page 12 - Using the Turbo function

2This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (20

Page 13

20Cleaning the air conditionerCleaning the Full HD  lterWashable foam based Full HD  lter captures large particles from the air. The  lter is clean

Page 14 - Setting the Current time

ENGLISH21Maintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it

Page 15 - Setting on timer

22TroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTION

Page 16 - Using the SPi function

23ENGLISHPROBLEM SOLUTIONError is indicated. • If error indicator such as , , , , , , , All blink, , , , , , , , , , , , , , , ,

Page 17 - Using the Auto Clean function

24Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.•Alwaysdisconnecttheaircondi

Page 18 - AAUsing the Quiet function

ENGLISH25Installing the unitIMPORTANT: When installing the unit, always remember to connect rst the refrigerant tubes, then the electrical lines. A

Page 19 - Cleaning the air conditioner

26Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rainWhere neighbors a

Page 20

27ENGLISHSpace Requirements for Outdoor UnitWhen installing 1 outdoor unitWhen installing more than 1 outdoor unit300 or more◆ When the air outlet is

Page 21 - Periodical checks

28Choosing the installation location(Unit : mm)◆ When the upper part of the outdoor unit and the air outlet is opposite the wall◆ When the walls are b

Page 22 - Troubleshooting

ENGLISH29Fixing the installation plateThe following connection accessories are optional. If they are not supplied, you should obtain them before insta

Page 23

ENGLISH3Safety precautionsBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and ecientl

Page 24 - Safety precautions

30Wall<20mmPlastic AnchorFixing the installation plate3. Fix the indoor unit.If you x the indoor unit on a wall (1) Fix the installation plate

Page 25 - Indoor unit

ENGLISH311. Extend the assembly cable if necessary.2 . Open the front grille.3 . Remove the screw securing the connector cover.4 . Pass the assemb

Page 26 - Outdoor Unit

32Installing and connecting the assembly pipe of the indoor unit1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit u

Page 27

ENGLISH33Purging the indoor unit1. Unscrew the caps at the end of each pipe.   All inert gas exhausts from the indoor unit. 1. Make sure that yo

Page 28 - Accessories

34Cutting or extending the pipeOuter Diameter Torque (kgf•cm)ø6.35 mm 140~170ø9.52 mm 250~280ø12.70 mm 380~420ø15.88 mm 440~480ø19.05 mm 990~1210ø22.2

Page 29 - Fixing the installation plate

ENGLISH35• Thehosewillbexedpermanentlyintopositionafternishingtheinstallationandthegasleaktest;refertopage39~40 for further de

Page 30 - Connecting the assembly cable

36Installing and connecting the drain hose of the outdoor unitWhile heating, ice may accumulate. During the process of defrosting, check if condensati

Page 31

ENGLISH373. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture.4. Open the valve of t

Page 32

38Purging the connected pipesRefrigerant type GWP valueR410A 1975 GWP=Global Warming PotentialIndoor unitOutdoor unit= ( ) kg= ( ) kg+= ( ) kg

Page 33 - Cutting or extending the pipe

ENGLISH39Performing the gas leak testsCDABMake sure to check for gas leaks before completing the installation process (connecting the assembly pipe an

Page 34

4Safety precautionsFOR POWER SUPPLYWARNINGRemove all foreign substances such as dust or water from the power plug terminals and contact points using a

Page 35 - Drain hose installation

40Fixing the indoor unit in placeInsulationPipes'X' mmRubber leg'Y' mmPerform the following work on the area where gas leak test w

Page 36 - Purging the connected pipes

ENGLISH41Final Check and Trial OperationTo complete the installation, perform the following checks and tests to ensure that the air conditioner operat

Page 37 - Adding Refrigerant

42How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1.

Page 38

ENGLISH43Sub PCB installation(optional)(Wried remote controller, central remote controller etc.)1. Turn the power o and take o the front panel of t

Page 39 - Performing the gas leak tests

QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT ALBANIA 42 27 5755AUSTRIA0810 - SAMSUNG (7267864, € 0.07/min)www.samsung.comBELGIUM 02-201

Page 40

AQV09K SeriesAQV12K SeriesAQV18K SeriesAQV09Y SeriesAQV12Y SeriesAQV18Y SeriesAir Conditioneruser & installation manualimagine the possibili

Page 41

5ENGLISHFOR USINGWARNINGDo not place an object near the outdoor unit that allows children to climb onto the machine. This may result in children ser

Page 42

6Operation rangesThe table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for eci

Page 43

ENGLISH7Main partsDisplayTimer indicatord'light Cool indicatorRemote controller receiverYour air conditioner may slightly look di erent from ill

Page 44 - QUESTIONS OR COMMENTS?

8Checking the remote controllerRemote controller buttons• Pointtheremotecontrollertowardstheremotecontrollerreceiveroftheindoorunit.• W

Page 45 - Air Conditioner

9ENGLISHRemote controller display• Thesignalmaynotbereceivedwellofelectroniclightingstyleuorescentlampssuchasinverteruorescentl