QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT INDIA1800 3000 8282 - Toll Free1800 266 8282 - Toll Freewww.samsung.com/in/supportThis prod
FOR USINGCAUTIONDo not place objects or devices under the indoor unit. Water dripping from the indoor unit may result in fire or property damage.Chec
FOR CLEANINGWARNINGDo not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean the appliance. Thi
Checking before useSmart install Through Smart install function, installer can check if the installation was done properly. If the installation w
Main partsYour air conditioner may slightly look dierent from illustration shown below depending on your model.Checking the name of the partsDisplayA
Checking the remote controllerRemote controller buttons• Pointtheremotecontrollertowardstheremotecontrollerreceiveroftheindoorunit.• Wh
Remote controller display• Thesignalmaynotbereceivedproperlyifelectronicourescentlampssuchasinverterourescentlampsareoperating in
Basic functionBasic operation is an operation mode that can be selected by pressing the Mode button. AutoIn Auto mode, the air conditioner will automa
Basic functionPress the button to turn on the air conditioner.Press the button to set the operating mode.• EachtimeyoupresstheMode button, th
Adjusting the air flow directionAir ow can be directed to your desired position.Vertical air owHorizontal air ow Move the blade pin lever left or r
Setting the On/Off timerSetting the On timerWhen the air conditioner is off; Remote controller display1. Press the Timer button to select (On). - (On)
AR12JV5HATQAR18JV5HATQAR18JV5HBTQAR12JV5HBWKAR18JV5HBWKAR24JV5HBWKAir Conditioneruser & installation manual(include Warranty Card)imagine the poss
Setting the Off timerWhen the air conditioner is on; Remote controller display1. Press the Timer button to select (Off). - (Off ) indicator will keep b
modeFor a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage. When the air condit
2-Step cooling function2-Step cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temp
Using the Fast functionUsing the Comfort functionYou can set the Comfort function to provide mild cooling.When the air conditioner is operating in Coo
Using the Single User functionThis function will reduce the energy usage while the air conditioner is operating in Cool mode.When the air conditioner
Using the Quiet functionYou can reduce the noise generated from an indoor unit during Cool mode.When the air conditioner is operating in Cool mode; R
Using the Auto Clean functionAuto clean function will minimise the moisture inside of the indoor unit. Activate this function to help provide you with
Cleaning the air conditionerCleaning the indoor unit Clean the product with a tepid damp cloth. Remove the dust accumulated in the gap of the prod
Cleaning the outdoor unit heat exchanger When dust accumulates on the heat exchanger, it may decrease cooling performance. Therefore, clean it regul
Cleaning the air conditioner• Clean the Air filter every 2 weeks. Cleaning term may differ depending on the usage and environmental conditions. In dust
(Applicable in countries with separate collection systems)This marking on the product, accessories or literature indicates that the product and its el
Maintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best
TroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTIONTh
PROBLEM SOLUTIONFan speed adjustment is not working.• CheckifyouhaveselectedAuto/Dry/Fast/ mode. In these modes, fan speed is set to Auto and y
Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.•Alwaysdisconnecttheairconditi
Installing the unitIMPORTANT:Wheninstallingtheunit,alwaysremembertoconnectrsttherefrigeranttubes,thentheelectricallines. Always dis
Choosing the installation locationOutdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Where possible keep ou
Space Requirements for Outdoor UnitWhen installing 1 outdoor unit300 or more When the air outlet is opposite the wall1500 or more When the air out
(Unit : mm) When the upper part of the outdoor unit and the air outlet is opposite the wall When the walls are blocking front and the rear side of
AccessoriesThe following accessories are supplied with the air conditioner:• The number of each accessory is indicated in parentheses.Accessories in
1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants
ContentsPreparationSafety precautions ...4Check
Connecting the assembly cableCable specificationModel Interconnection cable12/18 4G X 1.5mm², H07RN-F243G X 1.0mm², H07RN-F1 X 0.75mm², H05RN-F
Connecting the assembly cable9. Connect the cables to the terminals as seen in the picture.• Each wire is labeled with the corresponding terminal nu
Installing and connecting the assembly pipe of the indoor unit1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unl
Evacuating the indoor unit• TheremainingairintheRefrigerationcycle,whichcontainsmoisture,may cause malfunction on the compressor.• Alway
4. Put a are nut slightly into the pipe and modify the are.Outer Diameter (D) Depth (A) Flaring Size (B)ø6.35 mm 1.3 mm 9.0 mmø9.52 mm 1.8 mm 13.0
Installing and connecting the drain hose of the indoor unitWhen installing the drain hose for the indoor unit, check if condensation draining is adequ
• Make sure the indoor unit is in upright position when you pour water to check for leakage.Make sure that the water does not overflow onto the electr
Evacuating the connected pipesThe outdoor unit is loaded with sufficient R-410A refrigerant. Do not vent R-410A into atmosphere: it is a fluorinatedgreen
Adding RefrigerantAdd refrigerant charge according to table below: If you use a pipe longer than 5m,15g of refrigerant R-410A must be added for each
Performing the gas leak testsCDABMake sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose be
Safety precautionsBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and eciently operat
Fixing the indoor unit in placeInsulationPipes'X'mmRubber leg'Y'mmPerform the following work on the area where gas leak test was
Smart Install modeThis model supports Smart Install mode which checks installation status to find out if there is any problems with any of the function
2) Smart Install mode in progress• 88 Display : Progress will be displayed in 0~99.• LED Display : Indicator on the indoor unit display will blink
Final check and trial operationTo complete the installation, perform the following checks and tests to ensure that the air conditioner operates correc
How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1. A
English-54RAC BORACAY_EN_Eco-inverter IBIM_05124A-00.indd 54 2014-12-18 오후 3:06:58
English-55RAC BORACAY_EN_Eco-inverter IBIM_05124A-00.indd 55 2014-12-18 오후 3:06:58
Do not install this appliance near a heater, inammable material. Do not install this appliance in a humid, oily or dusty location, in a location expo
Safety precautionsFOR POWER SUPPLYWARNINGRemove all foreign substances such as dust or water from the power plug terminals and contact points using a
FOR USINGWARNINGIf the appliance is ooded, please contact your nearest service center. Failure to do so may result in electric shock or fire.If the
Safety precautionsFOR USINGWARNINGDo not insert your ngers or foreign substances into the outlet when the air conditioner is operating. Take specia
Comments to this Manuals