E-10Connecting the cableTwo electronic cables must be connected to the outdoor unit. The connection cord between indoor unit and outdoor unit. The

Page 3 - Contents

E-11ENGLISHConnecting the cableWiring Diagram of Power CableWhen using ELB for 1 phasePower SupplyElectrical component boxIndoor Unit Outdoor unitELB

Page 4 - A Type:

E-12Wiring Diagram of Connection CordConnecting the cable (Continued)1(L)2(N)3(C) 3(C)F1 F2  V1 V1 F3 F4Outdoor unit 1(L)2

Page 5 - Wire rope

E-13ENGLISH When connecting cables, you can connect the cables to the electrical part or connect them through the holes below depending on the spot

Page 6 - Outdoor Unit

E-14Connecting the refrigerant pipeL1L0HRefrigerant Piping SystemRefrigerant piping system tablePipe length or heightDH18BTX1FC24BTVX1DH24BTX1CC24BTVX

Page 7 - Unit : mm

E-15ENGLISHThe air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor either

Page 8

E-16Cutting/Flaring the pipes1Make sure that you have the required tools available. (pipe cutter, reamer, flaring tool and pipe holder)2If you wish t

Page 9 - Outdoor unit installation

E-17ENGLISHPerforming leak testsBA The designs and shape are subject to change according to the model.LEAK TEST WITH NITROGEN (before opening valves

Page 10 - Connecting the cable

E-18Connecting the drain hose to the outdoor unitInsulationNo gapNBR(T13.0 or thicker)When using the air conditioner in the heating mode, ice may accu

Page 11

E-19ENGLISHTo Open the Stop ValveTo Close the Stop Valve1Remove the cap.2Turn the stop valve clockwise by using a hexagonal wrench.3Tighten the axis u

Page 12 - FC24BTV

E-2Safety Precautions(Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.)WARNING• Alw

Page 13 - Connecting the Power Terminal

E-20Model“A”(R22)Outdoor UnitIndoor UnitFC24BTVX1 FC24BTVA115g/mCC24BTVX1 CC24BTVA125g/mDC18ETSX1 DC18ETSA125g/mCC24ETVX1 CC24ETVA125g/mDH18BTX1 DH18B

Page 14 - Refrigerant Piping System

E-21ENGLISHPump down ProcedurePump down will be carried out when an evaporator is replaced or when the unit is relocated in another area.1Remove the c

Page 15

E-22Terminal M4PVC-insulated green/ yellow wireTo grounding screwSteel coreCarbon plastic50cm30cmChecking correct groundingIf the power distribution c

Page 16 - Cutting/Flaring the pipes

E-23ENGLISHSetting Up Option Switches  Except for cooling only models (The outdoor unit PCB is not applied to the cooling only models)K1 K3K2CHECK MO

Page 17 - Performing leak tests

E-24Setting up Option Switches (Continued)K1K2K3K412312341234567Adding refrigerant for heat pump modelsTest operation for heat pump modelsEndAdding r

Page 18 - Insulation

E-25ENGLISHTesting Operations1 Check the power supply between the outdoor unit and the auxiliary circuit breaker.◆ Single phase power supply: L, N

Page 19 - Using stop valve

E-26TroubleshootingOutdoor unit◆ If an error occurs during the operation, it is displayed on the outdoor unit PCB. High temperature of Discharge (

Page 22 - Checking correct grounding

ENGLISHINSTALLATION MANUALESPAÑOLSystem Air Conditioner SE A DB98-31088A(1)This product is not manufactured for Iran. SVC Warranty will not be applica

Page 23 - Setting Up Option Switches

E-3ENGLISHContents Preparation for outdoor unit installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Deciding on where

Page 24

E-4B Type: FC18BTVX1C Type: DH18BTX1 FC24BTVX1 DH24BTX1 CC24ETVX1 CC24BTVX1Pr

Page 25 - Testing Operations

E-5ENGLISHMoving the Outdoor Unit by Wire RopeFasten the outdoor unit by two 8m or longer wire ropes as shown at the figure. To prevent from damage or

Page 26 - Troubleshooting

E-6Deciding on where to install the outdoor unit If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position. 

Page 27

E-7ENGLISHDeciding on where to install the outdoor unit300 or more When the air outlet is opposite the wall1500 or more When the air outlet is t

Page 28

E-8Deciding on where to install the outdoor unit (Continued)Unit : mm1500 or more When the air outlet is towards the wall300 or more300 or more1500

Page 29 - INSTALLATION

E-9ENGLISHOutdoor unit installationMake a drain outlet around the base for outdoor unit drainage.If the outdoor unit is installed on the roof, y