• Thearenutsareattachedtotheendofeachpipeofanevaporatororaserviceport.
Use the nuts when connecting the pipes.
• Thewireassemblycableisoptional.Ifitisnotsupplied,usethestandardcable.
• Thedrainplugandrubberlegareonlyincludedwhentheairconditionerissuppliedwithouttheassemblypipe
as seen in the picture below.
• Iftheseaccessoriesaresupplied,theywillbeintheaccessorybox.
4-wire
Assembly Cable (1)
✴✴
12/18/24
✴✴
Tools required for installation
General Tools
•VacuumPump(Backwardowingprevention) •ManifoldGauge •StudFinder
•TorqueWrench •PipeCutter •Reamer •PipeBender •SpiritLevel
•ScrewDriver •Spanner •Drill •LWrench •MeasuringTape
Tools for test operations
•Thermometer •ResistanceMeter •Electroscope
Fixing the installation plate
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before xing
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
Whenfacingthewall,thepipeandcablecanbeconnectedfromthe:
A
C
B
D
D
Direction of pipe
•Right(A)
•Left(B)
•Underside_right(C)
•Rear_rightorleft(D)
• You can install the refrigerant pipe in the left/right/bottom, or the rear side of the indoor unit.
• If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the
opposite direction as shown. Otherwise, the pipe may be damaged in the process.
Insulated Assembly Pipe,
Ø6.35 mm x 5 m (1)
✴✴
12/18
✴✴
Ø6.35 mm x 4 m (1)
✴✴
24
✴✴
Insulated Assembly Pipe,
Ø12.70 mm x 5 m (1)
✴✴
12/18
✴✴
Insulated Assembly Pipe,
Ø15.88 mm x 5 m (1) ✴✴24JFC✴✴
Ø15.88 mm x 4 m (1) ✴✴24JFB✴✴
PE T3 Foam Tube
Insulation (1)
Vinyl Tapes (2)
Drain Hose,
length 2 m (1)
Putty 100 g (1) Pipe Clamps A (3) Pipe Clamps B (3) Cement Nails (6)
M4 x 25 Tapped
Screws (6)
The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air
conditioner.