FJM CONSOLE_IM_29317A_E_10.16.08.indd 1 2008-11-24 15:41:20

Page 2 - Safety Precautions

E-10From factory the unit is supplied and set with a pre-charge of nitrogen gas (insert gas). Therefore, all insert gas must be purged before connecti

Page 3 - WARNING

E-11ENGLISHConnecting the refrigerant pipeThere are two refrigerant pipes of different diameters: A smaller one for the liquid refrigerant A larger

Page 4

E-12Cutting/Flaring the pipesCAUTIONIn case of welding the pipe, you must weld with nitrogen gas blowing.Inclined Damaged Surface Cracked Uneven Thick

Page 5 - Contents

E-13ENGLISHPerforming leak test & insulationLEAK TEST WITH NITROGEN (before opening valves)In order to detect basic refrigerant leaks, before re

Page 6 - Preparation for installation

E-14Drain hose installationWhen installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain ho

Page 7 - Indoor unit

E-15ENGLISHConnecting the connection cordThe indoor unit is powered by the outdoor unit by means of a H07 RN-F connection cable (or a more power mode

Page 8 - Drawing of the indoor unit

E-16Assigning address to indoor unit1Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system

Page 9 - Indoor unit installation

E-17ENGLISHTroubleshooting   12345678901234567890Abnormal conditionsLED lamp displayRemarksWhitePower resetX X X X

Page 10 - Purging the unit

E-18Troubleshooting (Continued)Abnormal conditionsLED lamp displayRemarksWhite[Self diagnosis]Power voltage detection between indoor and outdoor unit

Page 11 - Spring pipe

E-19ENGLISHTroubleshooting (Continued)Display Explanation RemarkNo feedback errorIndoor unit Communication ErrorIndoor/Outdoor unit Communication Time

Page 12 - Cutting/Flaring the pipes

E-2Safety PrecautionsKeep this installation manual together with the user’s manual in a handy place so that you can find it whenever you need to see i

Page 13 - Insulation

E-20Additional accessoriesCentralized control1Cable-tie Cable clampM4x16 tapped screwUser's manualInstallation manual2 5 7 1 1Centralized contr

Page 14 - Drain hose installation

E-21ENGLISHAdditional accessoriesFunction control1Cable-tie Cable clampM4x16 tapped screwUser's manualInstallation manual2 6 7 1 1Function con

Page 15 - Wiring diagram

FJM CONSOLE_IM_29317A_E_10.16.08.indd 22 2008-11-24 15:41:46"EEE Yönetmeliğine Uygundur" "This EEE is compliant with RoHS"

Page 16

ENGLISHFree Joint Multi Air Conditioner (Cooling and Heating) INSTALLATION MANUALMHFJEA SeriesESPAÑOLFRANÇAISITALIANOPORTUGUÊSDEUTSCHEΛΛHNIKA DB

Page 17 - Troubleshooting

E-3ENGLISHWARNING  This indicates the possibility of serious injury or death. Installation must be carried out by a qualified installer.Installers

Page 18 - Troubleshooting (Continued)

E-4CAUTION This indicates the possibility of serious injury or damage to environments when operated incorrectly.Check the unit for damage that may

Page 19

E-5ENGLISHContents Preparation for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 20 - Additional accessories

E-6Preparation for installationWhen deciding on the location of the air conditioner with the owner, the following restrictions must be taken into acc

Page 21

E-7ENGLISHDeciding on where to install the indoor unitIndoor unitThis unit has to be installed as floor type only. There must be no obstacles nea

Page 22

E-8Drawing of the indoor unitDeciding on where to install the indoor unit (Continued)720Length of pipes and difference in height: see the outdoor un

Page 23 - INSTALLATION

E-9ENGLISH1When you install the indoor with side-pipe connection, please make space more than 300mm from the wall at the pipe connection direction.2Wh