3-2-4 LED display indication in case of error detection
Samsung Electronics 3-3
3-2-5 Panel key operation
Key operational function Key Type
Operation/Stop Start and stop of operation
- Once ON=start of operation, again ON=stop of operation TACT
- No operation continuously.
Function selection Change of the operation mode(in case of the model option cooling only)
- It is selected with "COOL FAN"(default=COOL) for each once turn on. TACT
- In case that the operation off, it is treated invalidity.
- No operation continuously.
Flow wind selection Set the fan motor speed
- It is selected with
"HIGH MED LOW HIGH" for each once turn on. TACT
- In case that the operation off, it is treated invalidity.
- No operation continuously.
Temperature It is increased the desired temperature that displayed now.
adjustment - The desired temperature is increased for each pressing with 1°… unit.
(increase) (Increase:18˚C 19˚C .. 21˚C .. 23˚C .. 29˚C 30˚C
64˚F 65˚F .. 70˚F .. 80˚F .. 85˚F 86˚F)
- In case that the desired temperature is 30˚C, 86˚F…, if the
"increase key is pressed, it is not increased. TACT
If you press the "Increase/Decrease" key of the remote controller,
it occurs the alarm horn at above status.
- It is possible a single shot and continue operation.
- In case of the operation off and flow wind operation, it is treated invalidity.
Temperature It is decreased the desired temperature that displayed now.
adjustment - The desired temperature is decreased for each pressing with 1˚... unit.
(decrease) (Decrease:30˚C 29˚C .. 23˚C .. 21˚C .. 19˚C 18˚C
86˚F 85˚F .. 80˚F .. 70˚F .. 65˚F 64˚F)
- In case that the desired temperature is 18˚C, 64˚F…, if the
"decrease key is pressed, it is not decreased. TACT
If you press the "Increase/Decrease" key of the remote controller, it occurs the alarm
horn at above status.
- t is possible a single shot and continue operation.
- In case of the operation off and flow wind operation, it is treated invalidity.
Key description
Key name
Installation and Operating Instructions
1. Set operation in case of error occurrence.
• Malfunction of each temperature sensor (open, short)
- Error mode display, warning sound.
- The operation status is off.
ERROR OPERATION
ROOM THERMISTOR
(OPEN OR SHORT)
7-SEG
LED DISPLAY(LE01)
E1 displayed
AW0690-00162A-1 5/16/00 11:33 AM Page 3-3
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 47 48

Comments to this Manuals