24
Gas Conversion
■ Be careful, the operations and adjustments to be carried out when converting
from one gas to another.
■ All work must be carried out by a qualified technician.
■ Before you begin, turn off the gas and electricity supply to the appliance.
Change the injector of the burners.
1
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and replace it with
the stipulated injector for new gas supply. ( see table 1. Page 25.)
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly tighten the
injector in place.
Adjusting of the taps of the cooking hob burners for
reduced consumption
2
➀ Turn the taps down to minimum.
➁ Remove the control handles from taps.
➂ Adjusting the by-pass screw.
- For converting G20 into G30 or G31, the screw must
be screwed down fully tight.
- At this stage, light up the burners and turn the
control handles from max position to minimum
position to check flame stability.
- For converting G30 or G31 into G20, please contact
“After-Sales Service”.
➃ Replace the control handles on the taps.
Injector
Control handle
Tap
Sealing ring
Tap
by-pass screw
■
Do not dismantle the tap shaft : in the event of a malfunction, change the whole tap.
■ Before placing the burners back on the top place, make sure that the injector is
not blocked.
■ A full operational test and a test for possible leakages must be carried out after
gas conversion. (such as soap water or gas detector)
■ After completing conversion, a qualified technician or installer has to mark “V”
on the right gas category
to match with the setting
in rating plate.
Remove the previous
setting “V” mark.
GN641FFBD S/N: A36579MZ400007A
G20/20mbar 220-240V 50/60Hz, Pmax 1W
∑Qn Q20: 7.5kW G30: 521g/h G31: 503g/h
G20-20mbar
G30/29mbar
G31/37mbar GB Cat.: ll 2H3+
0063