Refrigeration Troubleshooting
The Forced Operation Mode is a valuable troubleshooting tool for testing
compressor operation & some fan operation.
Forced Freeze (FF) Mode
• The compressor is started without the 5-7 minute delay
You can accurately check defrost sensor voltages in this mode with
the cold evaporators.
You can check the compressor current draw or check voltage at the
main PCB in this mode.
• Some fans will be turned on in this mode, to allow voltage testing. The
door switches still control the fan operation. (Fridge fan is still
controlled by the compartment sensor, Cond fan by the ambient sensor)
.
• Inverter Compressors (most models), 3 speeds (FF1, FF2, FF3) can be
selected and check some fans, current draw or compressor control
voltage in the Forced Operation. (Fridge fan is still controlled by the
compartment sensor, Cond fan by the ambient sensor)
ASK
TEST
RESULTS