Confidential MAX8698C, Rev08
Page 9/47
DO NOT COPY. DO NOT DISTRIBUTE 12/8/2009
PARAMETER CONDITIONS MIN TYP MAX UNIT
T
A
= 25°C
-1 0 1
ONO\, RSO\, LBO\
Output High Leakage
V
IN5
= 5.5V
T
A
= 85°C
0.1
uA
MR\ Pull-up resistor to V
IN5
400 800 1600
kΩ
PWRON Pull-down resistor to
GND
400 800 1600
kΩ
JIGON Pull-down resistor to GND
400 800 1600
kΩ
RSO\ De-assert Delay
60 msec
Note1. Design guidance only, not tested during final test.
Buck Converter 1 & 2 Electrical Characteristics
Operating conditions (unless otherwise specified) V
IN1
to V
IN6
=
+3.7V, C
BATT+ΣIN_
=20μF, C
REFBP
= 100nF, T
A
=-40°
C to +85°C
PARAMETER CONDITIONS MIN TYP MAX UNIT
Ground Current I
LOAD
=0, no switching (Note1) 26
μA
Input Voltage Range 2.7 5.5 V
BUCK1 -3% 1.2 +3%
Default output Voltage I
Load
=100mA
BUCK2 -3% 1.2 +3%
V
Programmable Output Voltage
I
Load
=100mA, Programmable
Output Voltage Steps
(BUCK1 and BUCK2) =50mV
-3%
0.75
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.15
1.20
1.25
1.30
1.35
1.40
1.45
1.50
+3% V
Output Voltage Line regulation
V
IN1
to V
IN6
=
+2.7V to 5.5V
0.3 %/V
PFET Switch 1200 1600 2000 mA
Current Limit
NFET Rectifier 800 1200 1600 mA
PFET Switch, I
LX
= -150mA 0.2
Ω
On-Resistance
NFET Rectifier, I
LX
= 150mA 0.11
Ω
Rectifier Off Current Threshold 40 mA
Minimum On- and Off-Times
Ton 70 nsec