Fast Track Troubleshooting
IMPORTANT SAFETY NOTICE – “For Technicians Only” This information is published for
informational purposes only and intended for use only by personnel qualified for the specific tasks depicted.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when handling or servicing a product. Only qualified personnel should repair
products powered by electricity. Any attempt to handle, service or repair the product or products by anyone
other than qualified personnel could result in serious injury or death. You agree that your use of and reliance
on this information is at your sole risk. This information is subject to change or update without notice. There
are no warranties, either expressed or implied, regarding the accuracy or completeness of this information”
Models Covered:
RSG307AABP
RSG307AARS
RSG307AAWP
Publication # jsRSG307AA Revision Date 03/02/2012
Component Value Chart
Sales Mode
No Compressor Operation
Press the Settings
Icon on the screen,
scroll to the second
page of the menu and
toggle the setting
Installation Note:
2” space required top and
rear and 3 3/4” space re-
quired on sides
Sealed System
Refrigerant Charge
R134a 5.64 oz.
SUPPORT INFORMATION
Training — Plus One
http://my.plus1solutions.net/clientPortals/samsung/
Help — GSPN
http://service.samsungportal.com/
Component Resistance Wattage Voltage
Freezer Defrost Heater 62.6Ω 230 120vac
Fridge Defrost Heater 120Ω 120 120vac
French Mullion Heater 1446Ω 10 120vac
Ice Duct Heater 2057Ω 7 120vac
Dispenser Heater 5760Ω 2.5 120vac
Ice Maker Heater 93Ω 156 120vac
Damper 144Ω 1 12vdc
Sensors 2.5kΩ-89kΩ N/A 1~4.5vdc
Fans N/A N/A 7~12vdc
Forced Mode: Press both buttons (Power Freeze– Fridge) simultaneously (No
sound when both buttons are pressed at the same time) ‘til it beeps and goes
blank, 8-12
seconds
3600RPM 2450RPM 2200RPM
Press Freezer button one
time at the Test Mode to
Force Compressor High
Speed Run, measure fan
and Compressor volt-
ages at main PCB
Press Freezer button a
second time to Force
Press Freezer button a
third time to Force Low
Press Freezer button a
forth time to Force De-
frost of Fridge & Freezer,
measure defrost voltage
at main PCB
Sales Mode, No Compressor Operation
Press Power Freeze & Freezer temp buttons
simultaneously for 3 sec ( you will hear a “Ding
Dong”) to remove or put into Sales Mode. When in
the Sales Mode the Display will show "OF" "OF"
Removing power will not cancel this mode.