Page view 65
the application, they would not be able to shut down the system or change the
passwords.
Subscriber Admin This effects only the GUI. This also works only with the
GUI and allows access to the following: Subscriber List, Display User Log, and
Status Screen.
Min Recorded Length This parameter sets the minimum record time that is to
be considered valid. It is specified in hundredths of seconds. A setting of 50
means 0.5 seconds or 500 milliseconds. The default value is 75. If this value is
too high, short recordings will be discarded. If it is too low, the system will
consider disconnects as a valid recording.
Dial Tone Trim Size This amount is trimmed off the end of any recorded mes-
sage that is terminated by dial tone. This parameter is measured in hundredths
of seconds.
Detect on leading edge Not used.
Minimum DTMF Duration This parameter controls the sensitivity of the DTMF
(touch-tone) detectors only during recording of voice prompts and announce-
ments. The value represents the minimum time period (in hundredths of sec-
onds) during which a tone must be valid in order to be accepted as a caller
entry. A lower value makes the SVMi-4 more sensitive to DTMF tones. If exces-
Programming - Page 63