Air Conditioner
installation manual
imagine the possibilities
Thank you for purchasing this Samsung product.
Cassette Type Series
1 Way cassette : AM

FN1DEH
AM

HN1DEH
AM

JN1DEH
2 Way cassette : AM

FN2DEH
4 Way cassette : AM

FN4DEH
AM

KN4FEH
DB68-03565A-09
EN
DVM S CASSETTE_IM_03565A-09_EN.indd 1 2017-06-07 오전 8:58:44
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Air Conditioner

Air Conditionerinstallation manualimagine the possibilitiesThank you for purchasing this Samsung product.Cassette Type Series1 Way cassette : AMFN

Page 2 - Contents

10Selecting the Installation LocationUnit : mmAMFN4DEH/AMKN4FEHAB890~910 (Celling opening)950735 (Suspension position)890~910 (Celling opening

Page 3 - Safety Precautions(Continued)

11Indoor Unit InstallationConcreteSuspension bolt(ø9.52 or M10)Hole in anchorHole in plugInsertCeiling supportIt is recommended to install the Y- join

Page 4

126Adjust the height of the indoor unit by using jigs. You should adjust the jigs and the pattern sheet to fit the cutting dimensions of ceiling.

Page 5 - AMN1DEH

13Connecting the Refrigerant PipeThere are two refrigerant pipes of differing diameters: A smaller one for the liquid refrigerant A larger o

Page 6 - Insulation Guide

14Cutting/Flaring the Pipes1Make sure that you prepared the required tools. (pipe cutter, reamer, flaring tool and pipe holder)2If you want to shorte

Page 7

15Outer diameter (D, mm)Connection TorqueFlare dimension (A, mm)Flare shape (mm)kgf•cm N•m6.35 140~180 14~18 8.70~ 9.109.52 350~430 34~42 12.80~ 13.20

Page 8

16Performing Leak Test & Insulation (Continued) 5Select the insulation of the refrigerant pipe.  Insulate the gas side and liquid side pipe re

Page 9

17 Drain pipe and Drain Hose InstallationInsulation drainpipeBandBandFlexible hoseDrain hose portDrainpipeAdhesivesInsulation cover bandInsulation co

Page 10 - Dimension of the indoor unit

18Drainpipe Connection 1The drain pipe should be installed within 100mm from the flexible hose, lift up from 100mm to 550mm and lift down 20mm or mor

Page 11 - Indoor Unit Installation

19Centralized Drainage 1Install main air vent at the front of the farthest indoor unit from the main drain when installed indoor units are more than 3

Page 12 - Purging the Unit

2Contents Safety Precautions ... 2 Accessories ...

Page 13

20Silver solderN LN L N L N LIndoor Unit 1Outdoor UnitIndoor Unit 2 Indoor Unit 3Wired Remote Control220-240V~h ELB : Essential InstallationEEV kitIn

Page 14 - Cutting/Flaring the Pipes

21Wiring Workh Rating currentUnit ModelRating currentAMFN1DEH0220280360.200.230.25AMHN1DEH0170220.140.15AMJN1DEH056

Page 15 - Insulation

22  Select the power cable in accordance with relevant local and national regulations.  Wire size must comply with local and national code.  Power

Page 16

231Prepare the following tools.Tools Crimping pliersConnection sleeve (mm)Insulation tapeContraction tube (mm)Spec MH-14 20xØ6.5(HxOD) Width 19mm 70xØ

Page 17

24Wiring Work (Continued)5Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape. A to

Page 18 - Centralized Drainage

25Setting an indoor unit address and installation optionSet the indoor unit address and installation option with remote controller option. Set the eac

Page 19 -

26Option setting Status1. Setting SEG2, SEG3 optionPress Low Fan button(∨) to enter SEG2 value.Press High Fan button(∧) to enter SEG3 value.Each time

Page 20 - Wiring Work

27Setting an indoor unit address and installation option (Continued)Option setting Status12. Setting Cool mode Press Mode button to be change to Cool

Page 21

281.Check whether power is supplied or not. - When the indoor unit is not plugged in, there should be additional power supply in the indoor unit.2.

Page 22 - Wiring Work (Continued)

29Setting an indoor unit address and installation option (Continued)1.Check whether power is supplied or not. - When the indoor unit is not plugged i

Page 23

3installinG the unitIMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always d

Page 24

30Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX 02 series installation option(Detailed)Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6Explanation PAGE MODE Use of

Page 25 - MR-EC00, MR-EH00

31Setting an indoor unit address and installation option (Continued)* Advanced function: Controlling cooling/heating current or power saving with mot

Page 26 - Option setting Status

32Option No. : 05XXXX-1XXXXX-2XXXXX-3XXXXX 05 series installation option(Detailed)Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6Explanation PAGE MODEUse of A

Page 27

33(*1) Height dierence : The dierence of the height between the corresponding indoor unit and the indoor unit installed at the lowest place. For

Page 28 - Indoor Unit

34SEG 3, 4, 5, 6, 8, 9 additional informationWhen the SEG 3 is set as "1" and follow Auto Change Over for HR only operation, it will operat

Page 29 - 02 series installation option

35Changing a particular option Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6Explanation PAGE MODEThe option mode you want to changeThe tens’ digit of an optio

Page 30

36Final Checks and User TipsTo complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly

Page 31 -  Do not install the

37Troubleshooting 1 Way cassette / 2 Way cassette If an error occurs during the operation, an LED flickers and the operation is stopped except the

Page 32 - 05 series installation option

38Troubleshooting(Continued) 1 Way cassette / 2 Way cassette(Continued)Abnormal condition Error codeLED DisplayOperation Defrost Timer FilterError on

Page 33

39Troubleshooting(Continued)Abnormal condition Error codeLED DisplayOperation Defrost Timer Filter1. When there is no communication between the indoo

Page 34

4AccessoriesSelecting the Installation LocationThe following accessories are supplied with the indoor unit. The type and quantity may differ depending

Page 35 - Changing a particular option

This product is RoHS compliantDVM S CASSETTE_IM_03565A-09_EN.indd 40 2017-06-07 오전 8:59:07

Page 36 - Final Checks and User Tips

5Selecting the Installation Location (Continued)Space Requirements for Indoor Unit AMFN1DEH/AMHN1DEH/AMJN1DEH / AMFN2DEH

Page 37 - LED Display

6Selecting the Installation Location (Continued)Insulation Guide Indoor unit A B C D E2Way-Cst5.2~7.2kw (890x230x575)880x185 880x185 570x185 570x185 8

Page 38 - Troubleshooting(Continued)

7Selecting the Installation Location (Continued)Dimension of the indoor unitNo. Name DescriptionLiquid pipe connection ø6.35Gas pipe connection ø12.

Page 39

8Selecting the Installation Location (Continued)Unit : mmDimension of the indoor unitNo. Name DescriptionLiquid pipe connectionAM056JN1 : ø6.35 (

Page 40

9Selecting the Installation Location (Continued)No. Name DescriptionLiquid pipe connection056 : ø6.35071 : ø9.52Gas pipe connection056 :

Comments to this Manuals

No comments