28
Fixing the installation plate
Wall
<0.79inch
(20mm)
Plastic
Anchor
2. Fix the indoor unit.
If you x the indoor unit on a wall
(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.
If you x the indoor unit on a window frame
(1) Determine the positions of the wooden uprights to be
attached to the window frame.
(2) Attach the wooden uprights to the window frame giving
attention to the weight of the indoor unit.
(3) Attach the installation plate to the wooden upright using
tapping screws.
If you x the indoor unit on a gypsum board
(1) Use stud nder to nd out locations of the studs.
(2) Fix the plate hanger on two studs.
• Ifyoumounttheplatetoaconcretewallusingplasticanchors,makesurethat
gapsbetweenthewallandtheplate,createdbyprojectedanchor,islessthan
0.79inch(20mm).
• Searchforotherspotsiftherearelessthantwostuds,orthedistancebetweenthestudsaredierentfromthe
plate hanger.
• Fixtheinstallationplatewithoutincliningtooneside.
• Makesurethatawallcanwithstandtheweightoftheproduct.Ifyouinstalltheproductinaplacewhereitisnot
strongenoughtowithstandtheproductweight,theunitcouldfallandcauseinjury.
Connecting the assembly cable
• Connectthepowercabletotheauxiliarycircuitbreaker.Ifeverypolefailstoconnecttothe
powersupply,itmustbeincorporatedinawirewithacontactopeningof≥0.118inch(3mm).
Cable specication
Connecting the cable
Electrical work
(1)Forelectricalandearthworks,complywiththe‘technicalstandardsofelectricalinstallations’andthethe‘wiring
regulations’oftheElectricityEnterprisesAct.
(2)Tightentheterminalblockscrewto0.89~1.33lb•ft[1.2~1.8N•m(12~18kgf•cm)].
(3)Precautionswhenconnectingterminalblocksoftheindoorunit
Beforeconnecting,makesuretheconnectingpartoftheterminalsocketisfacingupwards.
Upside down
The terminal
socketisdamaged.
There is no ring
terminalto cover the wire.
Model Use AWG Cross sectional area (mm
2
)
09/12/18/24
Mainpowersupply3-wirePowercable 13 or fewer 2.5 or more
Indoorpowersupply3-wirepowercable 15 or fewer 1.5 or more
2-wireassemblycable 15 or fewer 1.5 or more
36
Mainpowersupply3-wirePowercable 10 or fewer 4ormore
Indoorpowersupply3-wirepowercable 15 or fewer 1.5 or more
2-wireassemblycable 15 or fewer 1.5 or more
Vivaldi MAX_AQN09VFU@@ IB&IM_32163A-3_EN.indd 28 2015/8/17 17:25:40