2 . Open the front grille.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.
(Refer to the picture below)
5 . Pass the other end of the cable through the 2.56inch(65mm) hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the front grille.
8 . Remove the terminal board cover on the side of the outdoor unit.
9. Connect the cables to the terminals as seen in the picture.
• Eachwireislabeledwiththecorrespondingterminalnumber.
1. Extend the assembly cable if necessary.
• Donotconnecttwoormoredierentcablestoextendthelength.
It may cause re.
When you install the unit, make rst refrigerant connections and then electrical connections.
Connect the air conditioner to grounding system before performing the electrical connection.
If unit is uninstalled, rst disconnect electrical cables, then refrigerant connections.
A 24.6ft(7.5m) pipe is supplied with the air conditioner. If the outdoor unit is more than 24.6ft(7.5m) away from the indoor
unit,you must extend the cable. The maximum length of the cable is 15(09/12)/20(18/24/36) meters.
• Eachwireislabeledwiththecorrespondingterminalnumber.
Indoor unit
Outdoor unit
There must be no space between the terminal and the screw when connected.
- Any remaining space may become are hazard due to overheating of the electrical contact.
The terminal socket
is upside down.
Either the screw is not fitted properly
or there is a space between the screw
and the ring terminal.
• Fortheterminalblockwiring,useawirewitharingterminalsocketonly.
Regular wires without a ring terminal socket may become a re hazard due to overheating
of the electrical contact during a wiring work.
Indoor unit
Outdoor unit
The appearance of the unit may be dierent from the diagram depending on the model.
L1 L2
L1
L2
F1
F2
F1
F2
L1 L2
F1
F2
09/12/18/24
36
L3
L4
L3 L4
F1
F2
L3
L4
F1
F2
L1 L2
F1
F2
Indoor unit
Outdoor unit