68_ setup screen
Post-alarm duration : The post alarm duration can be one among 5 seconds, 10
seconds, 15 seconds, and 30 seconds. You can send a post-alarm image of up
to 30 seconds after the alarm is triggered.
(The max time differs, depending on the frame rate)
The pre/post alarm duration is not available in SMTP transfer mode.
Only one image at the corresponding time will be transferred.
When done, click [Apply].
Your settings will be saved.
To set the alarm input
Select <Event> - <Alarm input 1> or
<Alarm input 2>.
The Alarm Input setup window appears.
When done, click [Apply].
Your settings will be saved.
Input device setup : Select an input
type according to the characteristics
of the alarm sensor installed in the
main unit.
Off : Turns off the alarm input setting.
NO (Normal Open) : It is normally open, but if it is closed, an alarm will be
triggered.
NC (Normal Close) : It is normally closed, but if it is open, an alarm will be
triggered.
Activation time : You can set a time to execute a specifi c command when an
alarm occurs.
Always : Always executes the specifi ed command when an alarm occurs.
Only scheduled time : Activates notifi cation as confi gured only when alarm
events occurred during the specifi ed time period.
Action : You can set an action to execute when an alarm occurs.
Alarm output : Set the alarm output port to which the alarm signal is transferred.
Output duration : Set the period of time to output the alarm signal to the
specifi ed alarm output port when an alarm occurs.
If a new alarm event is detected during the alarm output, the delay time is
recalculated based on the detection time of the recent alarm.
Alarm image transfer : If you select <On>, you can transfer JPEG images to a
registered address via FTP or SMTP server or save images into the SD memory card
according to the setting in <Event> - <Transfer setup>.
-