Samsung NX-308 User Manual Page 118

  • Download
  • Add to my manuals
  • Print
  • Page
    / 172
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 117
DISPLAY DESCRIPTION D E F A U L T RANGE
DOR R OFF controls the duration of ringing at the door 030SEC 1~250SEC
(Door Ring ring destination before canceling
OFF time)
FIRST DGT controls how long the system will wait for 025SEC 1~250SEC
(First Digit dialing to begin before dropping the dial tone
wait time) and initiating an error tone.
HOOK OFF controls the time before dial tone is sent to a 0200MS 100~
(Hook OFF single-line station. 2500MS
time)
INTER DGT controls the grace period between dialing 025SEC 1~250SEC
(Inter Digit valid digits before dropping the call and
duration) returning the user back to an error tone.
MMC OUT controls the grace period between programming 030SEC 1 0 ~ 2 5 0 S E C
(MMC actions while in a programming session, before
session time) returning system to secure programming status.
OFF R INT controls the duration of time between ring 015SEC 1~250SEC
(Off hook bursts to a user who has a camped-on call.
Ring Interval)
PAGE MAX controls the allowed duration of a page 020SEC 1~250SEC
(Page duration) announcement.
RCAL DISC this is the time an attendant recall will 002MIN 1~250MIN
(Recall ring before being disconnected.
Disconnect
time)
RCAL RING this is the length of time a transfer recall 015SEC 0~250SEC
(Recall Ring will ring at a station before recalling the
length) operator
RCAL WAIT after a transferred call is recalling at the transferring 015SEC 0~250SEC
(Recall station and the station is busy, this timer will expire
Waiting time) and transfer the call to the operator.
This only applies to trunk calls.
RCAL HOLD determines the time calls can be left on hold 045SEC 0~250SEC
(Recall Hold before recalling back to the holding station.
time)
RCAL TRSF determines the time transferred calls ring 045SEC 0~250SEC
(Recall before recalling.
Transfer time)
SLT F MIN monitors the duration of a hookswitch flash to ensure that 0350MS 100~
(minimum SLT the flash is valid and not a line transient or accidental 2500MS
Flash time) hookswitch bounce. It is the minimum time of single-line station.
SLT F MAX maximum time of hookswitch flash of a 0800MS 100~
(maximum SLT single-line station. 2500MS
flash time)
SMDR PULS this grace period timer starts SMDR recording 030SEC 1~250SEC
(SMDR start for pulse (rotary) dialing and controls the
time for rotary LCD duration timer on the keysets.
dialing)
SMDR DTMF this grace period timers starts SMDR recording 015SEC 1~250SEC
(SMDR start for DTMF (Touch Tone) dialing and controls
time for touchtone the LCD duration timer on the keysets.
dialing)
TRK DISC controls the duration of an outside call 030MIN 1~250MIN
NX-SERIES HYBRID KEY SYSTEM PROGRAMMING SECTION
MMC 50
4Programming 1999.9.15 12:43 PM 페이지49
Page view 117
1 2 ... 113 114 115 116 117 118 119 120 121 122 123 ... 171 172

Comments to this Manuals

No comments