troubleshooting _49
05 TROUBLESHOOTING
Symptom Checklist Measure to Take
The vacuum cleaning
robot frequently
collides with the
autoemptier.
Check whether the autoemptier• Turn on the power switch on the •
left side of the autoemptier.
Plug the power plug into the outlet.•
The auto-emptier
does not empty
the dustbin
automatically.
Check whether there is a foreign •
substance on the fi lter.
Clean the fi lter.•
Check whether there is a foreign •
substance inside the dustbin.
Remove the foreign substance •
from the inside of the dustbin.
The bottom of the autoemptier is •
clogged.
Open the bottom of the auto-•
emptier using a coin and then
remove the dust clogging it.
Check whether the dustbin •
cyclone cap exists.
Close the dustbin cyclone cap.•
Check whether the auto empty •
lamp of the auto-emptier is turned
on.
Press the Auto Empty On/Off •
Select button on the auto-emptier.
Check whether the dustbin is •
separated from the autoemptier.
Turn off the auto-emptier and then •
insert the dustbin fully until it is
mounted completely.
Check whether the fi lter is •
separated from the autoemptier
dustbin.
Turn off the auto-emptier and then •
mount the fi lter onto the dustbin.
Check whether the Power •
Brush wrapped in any foreign
substances.
Remove any foreign substances •
such as long hairs or strings
wrapped around the power brush.
The suction power of
the auto-emptier is
week.
Check whether the Full lamp is •
turned on.
Empty the dustbin.•
Clean the air inlet of bottom.•
Check whether the air inlet is •
clogged by a foreign substance.
Remove the foreign substance •
from the air inlet.
Check whether dust has collected •
on the fi lter.
Clean the fi lter.•
Check whether dust or hairs have •
collected on the cyclone.
Open the cyclone cap and then •
remove any dust and hair.
The vacuum cleaning
robot is not charged.
Check whether there is a foreign •
substance on the charging
terminals.
Remove the foreign substance •
from the charging terminals.
Turn on the power switch of the
auto-emptier.
Check whether the autoemptier is •
turned on.
DJ68-00632B.indb 49DJ68-00632B.indb 49 2012.1.19 11:52:47 AM2012.1.19 11:52:47 AM