Samsung SCC-C6453 User Manual Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 260
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
46_ setup
setup
COMMUNICATION
You can set the RS-485 communications setting in regard of the camera.
For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 20)
Select <MAIN MENU>-<COMMUNICATION>.
Select each item and set appropriately.
PRIORITY : Set the priority by selecting
<HW> or <SW>.
When selected <HW>, the protocol,
baud rate and address settings will
follow those settings of the adaptor
switch.
PROTOCOL, BAUD RATE, ADDRESS :
When selected <SW>, you can manually
set the protocol, baud rate and address.
SYSTEM INFO
You can check the system information.
For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 20)
Select <MAIN MENU>-<SYSTEM INFO>.
The current system information is displayed.
1.
2.
1.
2.
COMMUNICATION
RS485
PRIORITY HW
PROTOCOL SAMSUNG
HALF
BAUD RATE 9600
ADDRESS 0
SYSTEM INFO
TYPE 4
_
PTZ
_
NOR
_
N
PROTOCOL SAMSUNG
ADDRESS 0
COMM. TYPE HW, RS485, HALF
BAUD RATE 9600
SERIAL NO. 000000000000000
CAMERA VER. v1.00
_
00000
ALARM VER. v1.00
_
00000
00890A-NA_SCC-C6453N-ENG.indb 46 2009-08-05 오후 3:03:41
Page view 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 259 260

Comments to this Manuals

No comments