OfficeServ 7200 Installation Manual
© SAMSUNG Electronics Co., Ltd. 3-21
3.3.1.6 GSIMT
GSIMT (Gigabit Switch Interface Module TX) provides the Giga bit LAN interface of
Layer 2 and Layer 3 to support data network.
Set the jumper of the GSIMT.
Jumper Setting
y When using the internal rectifier: Connect the shunt pins (J3, J4) to pins 1 and 2.
y When using an external rectifier: Connect the shunt pins (J3, J4) to pins 2 and 3.
Set jumpers J3 and J4 in the GSIMT.
Figure 3.21 Setting the Jumpers of the GSIMT
J3
J4