Fixing the indoor unit in place
Insulation
Pipes
'X'
Rubber leg
'Y'
Perform the following work on the area where gas leak test was done priorly.
After checking for gas leaks in the system, insulate the pipe, hose and cables.
Then place the indoor unit on the installation plate.
1. To avoid condensation problems, wrap foam insulation (as shown in thegure) on a
part without insulation on the end of the pipes.
2. Wind the pipe, assembly cable and drain hose with vinyl tape.
3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the
indoor unit carefully so it does not project from the rear of the indoor unit.
4. Hook the indoor unit to the installation plate and move the unit to the right and left
until it is securely in place.
Install the outdoor unit in level on a stable base to avoid the generation of noise
and vibration, especially when installing the unit close to a neighbor.
If you install the outdoor unit in a place exposed to strong winds or at a height, x
it to an appropriate support (wall or ground).
1. Place the outdoor unit as indicated on the top of the unit to let the
discharged air out properly.
2. Fix the outdoor unit in level to an appropriate support using anchor bolts.
3. If the outdoor unit is exposed to strong winds, install shield plates around
the outdoor unit so that the fan can operate correctly.
5. Wrap the rest of the pipe with vinyl tape.
6. Attach the pipe to the wall using clamps (optional).
Installation
plate
Connecting
pipes
Vinyl tape
Drain hose
• Makesurepipedoesnotmovewhenyouinstalltheindooruniton
an installation plate.
Fixing the outdoor unit in place
• Ensurethewallwillbeabletosuspendtheweightofrackand
outdoorunit;
• Installtherackclosetothecolumnasmuchaspossible;
• Installpropergrommetinordertoreducenoiseandresidual
vibration transferred by outdoor unit towards wall.
Outdoor unit installed on the wall by rack
Soft rubber designed to cut off
vibration from rack to wall.
(not supplied with product)
Designed to cut off residual vibration
from outdoor unit to rack.
(not supplied with product)
• Securetherubberlegtopreventthegenerationofnoiseandvibration.
Model X Y

09/12/18

2.01ft
(612mm)
1.04ft
(317mm)

24

2.16ft
(660mm)
1.12ft
(340mm)

36

2.26ft
(690mm)
1.32ft
(403mm)