ENGLISH
Selecting solderless ring terminal
Select a compressed ring terminal of a power cable based on a nominal dimensions for cable.
Cover a compressed ring terminal and a connector part of the power cable and then connect it.
Silver solder
Nominal dimensions for cable (mm) 4/6 10 16 25 35 50 70
Nominal dimensions for screw (mm) 4 8 8 8 8 8 8 8 8 8
B
Standard dimension (mm) 9.5 15 15 16 12 16.5 16 22 22 24
Allowance (mm) ±0.2 ±0.2 ±0.2 ±0.3 ±0.3 ±0.3 ±0.4
D
Standard dimension (mm) 5.6 7.1 9 11.5 13.3 13.5 17.5
Allowance (mm)
+0.3
-0.2
+0.3
-0.2
+0.3
-0.2
+0.5
-0.2
+0.5
-0.2
+0.5
-0.2
+0.5
-0.4
d1
Standard dimension (mm) 3.4 4.5 5.8 7.7 9.4 11.4 13.3
Allowance (mm) ±0.2 ±0.2 ±0.2 ±0.2 ±0.2 ±0.3 ±0.4
E Min. 6 7.9 9.5 11 12.5 17.5 18.5
F Min. 5 9 9 13 15 13 13 13 14 20
L Max. 20 28.5 30 33 34 38 43 50 51
d2
Standard dimension (mm) 4.3 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4
Allowance (mm)
+ 0.2
0
+0.4
0
+0.4
0
+0.4
0
+0.4
0
+0.4
0
+0.4
0
+0.4
0
t Min. 0.9 1.15 1.45 1.7 1.8 1.8 2.0
PAC_아프리카 중동향AP80S0A_IBIM_34514A-02_EN.indd 43 2015-04-23 오후 2:18:59