Samsung RB2044SL User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
Slide 27
Forced Operation Function
Used to Test Sealed System Components
1)Compressor Check
2)Refrigerator Defrost Heater Check
3)Ref and Fr Defrost Heater Check
4)Cancellation of Function
Note: Unit will beep continuously as long as the unit
remains in forced operation function
The forced operation check allows a
forced check of the cooling system.
Each mode will operate until the
next mode is selected or until the
test is cancelled. The forced mode
cannot be activated if the unit is
defrosting either of the evaporator
coils.
The compressor will run for 24
hours and then begin cycling at -25
degrees centigrade in the freezer and
1 degree centigrade in the fresh food
compartment.
Loss of power will also cancel this
function. There is no delay in
compressor start so if there is high
head pressure, an overload condition
can be encountered.
The three individual tests are;
Forced compressor pull-down,
Refrigerator defrost check and
refrigerator and freezer defrost
check.
Slide 28
To enter the forced operation mode,
depress the Power Freeze and the
Fridge Temp buttons for eight
seconds.