Samsung RB2044SL User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
Slide 60
Main PCB Fan Motor Circuitry
Resistance checks of the Fans are
with connector CN72 disconnected.
The Freezer and condenser fan
operate in two speed modes. The
fresh food evaporator fan is only
operated at the lower speed.
Slide 61
Evaporator and condenser fan
output voltages can be checked at
the metal tab of the output
transistors. Reference to DC ground
which is the tab of the +5VDC
regulator.
Slide 62
All of the 120VAC outputs are
located along one edge of the
control board.
23
Page view 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 39 40

Comments to this Manuals

No comments