Samsung RSA1DTMG User Manual Page 50

  • Download
  • Add to my manuals
  • Print
  • Page
    / 95
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 49
TROUBLE SHOOTING
5) The 7-Segment Load Status is as follows.
a
b
c
d
e
f
g
a
b
c
d
e
f
g
Freezer Fridge
50
NO
ITEM Description Display Digital no.
Damper
OVER-LOAD MODE
Over 34 Ambient Temp
LOW-TEMP MODE
Less than 21 Ambient Temp
EXHIBIT MODE
Exhibition Mode On
COMPRESSOR COMP On
FREEZER FAN HIGH F-FAN HIGH RPM
FREEZER FAN LOW F-FAN LOW RPM
FREEZER DEFROST HEATER
F-DEF HEATER ON
CONDENSER FAN HIGH C-FAN HIGH RPM
CONDENSER FAN LOW C-FAN LOW RPM
DISPENSER HEATER
Dispenser Heater On
NORMAL CONDITIONS
& All Off(22~33
)
Fridge first digit g
Fridge second digit e
Fridge second digit f
Fridge second digit g
Freezer second digit a
Freezer second digit b
Freezer second digit c
Freezer second digit d
Freezer second digit e
Freezer second digit f
Freezer second digit g
Fridge second digit e,f LED all Off
Load Mode Check List
1
2
3
4
5
6
7
8
9
10
11
12
Fridge
(first)
Fridge
(second)
Fridge
(second)
Fridge
(second)
Freezer
(second)
Freezer
(second)
Freezer
(second)
Freezer
(second)
Freezer
(second)
Freezer
(second)
Freezer
(second)
Fridge
(second)
Damper Open
1) If the panel display is reset upon instant power failure, it will trigger nonsense calls at the call center.
To prevent this, the following measure is implemented into the unit. Upon the power supply, it initializes
the unit or brings back its previous settings based on the Freezer temperature.
2) Upon the initial power on, it checks its Freezer temperature and Freezer defrost.When one of them
, it is to be
considered as an instant power failure and it brings back all its previous
operation functions (Power
Freeze, Power Cool, Vacation, Freezer Settings, Fridge Setting
s, Ice
Type, Child Lock, etc) related to
the panel displ
ay.
3) When all of them higher than 10℃,
it is to be considered as a long-pe
riod power failure and it will initialize
t
he
panel display (Freezer: -20
, Fridge: 3 , Cubed).
4-1-4) Restoration of Previous Settings Upon Power Failure
lower than 10