2013 SAMSUNG System Air Conditioners
139
CAC System
Product Fiche
Energy Labeling Information (AC product)
Model name (Indoor/Outdoor) AC100FB4DEH / AC100FCADGH AC100FB4FEH / AC100FCAFEH AC100FB4PEH / AC100FCAPEH AC100FB4PEH / AC100FCAPGH AC100FBMDEH/EU / AC100FCADEH/EU
AC100FBMDEH/EU / AC100FCADGH/EU
AC100FBMSEH / AC100FCASEH
Sound Power Level (Inside/Outside)
dBA
58/68 60/68 59/66 59/66 65/68 65/68 65/69
Refrigerant name
1)
- R-410A R-410a R-410A R-410A R-410A R-410A R-410a
GWP - 1975 1975 1975 1975 1975 1975 1945
SEER 5.6 6.7 6.4 6.4 5.2 5.1 4.3
(QHUJ\HIÀFLHQF\FODVV6((5 - A+ A++ A++ A++ A A C
QCE
2)
(cooling season) kWh/a 625 522 547 547 673 686 814
Pdesignc kW 10.0 10.0 10.0 10.0 10.0 10.0 10.0
SCOP -3.8 4.3 4.2 4.2 3.7 3.5 3.4
(QHUJ\HIÀFLHQF\FODVV6&23 -A A+ A+ A+ A A A
QHE
3)
(heating season) kWh/a 2800 3419 3100 3100 2573 2720 2800
Other heating seasons suitable for use - N/A N/A N/A N/A N/A N/A N/A
Pdesignh (Average) kW 7.6 10.5 9.3 9.3 6.8 6.8 6.8
Pdesignh (Warmer)) kW - - -----
Pdesignh (Colder)) kW - - -----
Declared capacity at reference design conditions kW 7.6 10.5 9.3 9.3 6.8 6.8 6.8
Assumed backup heating capacity kW 0 0 00000
Model name (Indoor/Outdoor) AC071FBNDEH/EU / AC071FCADEH/EU AC071FBRDEH/EU / AC071FCADEH/EU AC090FB4DEH / AC090FCADEH AC090FB4PEH / AC090FCAPEH AC090FBMDEH/EU / AC090FCADEH/EU AC090FBMSEH / AC090FCASEH AC100FB4DEH/ AC100FCADEH
Sound Power Level (Inside/Outside)
dBA
58/66 63/67 57/68 58/67 65/67 65/68 58/69
Refrigerant name
1)
- R-410A R-410A R-410A R-410A R-410A R-410A R-410A
GWP - 1975 1975 1975 1975 1975 1975 1975
SEER 6.1 6.0 5.6 6.4 5.4 4.3 5.6
(QHUJ\HIÀFLHQF\FODVV6((5 - A++ A+ A+ A++ A C A+
QCE
2)
(cooling season) kWh/a 390 414 563 492 583 733 625
Pdesignc kW 6.8 7.1 9.0 9.0 9.0 9 10.0
SCOP -3.8 3.8 3.8 4.2 3.7 3.4 3.8
(QHUJ\HIÀFLHQF\FODVV6&23 -A A AA+A A A
QHE
3)
(heating season) kWh/a 1769 1842 2432 2533 2573 2800 2800
Other heating seasons suitable for use - N/A N/A N/A N/A N/A N/A N/A
Pdesignh (Average) kW 4.8 5.0 6.6 7.6 6.8 6.8 7.6
Pdesignh (Warmer)) kW - - -----
Pdesignh (Colder)) kW - - -----
Declared capacity at reference design conditions kW 4.8 5.0 6.6 7.6 6.8 6.8 7.6
Assumed backup heating capacity kW 0 0 00000
"1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP,
if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [1975]. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere,
the impact on global warming would be [1975] times higher than 1 kg of CO 2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble
the product yourself and always ask a professional."
"2) Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located."
"3) Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located."