5-17Samsung Electronics
5-4 Fault Diagnosis of Major Parts
Parts
Temp.Sensor
Heat ex. Sensor
Indoor Fan Motor
Outdoor Fan Motor
Stepping Motor
(UP/DOWN swing motor)
Diagnosis
Measure resistance with a tester.
Normal 8KΩ~27KΩ at ambient temperature (+0°C ~ +30°C)
Abnormal ∞, OΩ … open or short
Measure resistance between terminals (CN72) with a tester
Normal At ambient temperature (10°C ~ 30°C)
Abnormal ∞, OΩ … open or short
Measure the voltage between ground and signal wire of the fan motor
Normal
Abnormal Abnormal if voltage does not change from 0V to 5V.
Normal At ambient temperature (10°C ~ 30°C)
Abnormal ∞, OΩ … open or short
Measure resistance between red wire and each terminal.
Normal Approx. 380Ω at ambient temperature (20°C ~30°C)
Abnormal ∞, OΩ … open or short
between Resistance
Red, Yellow 190±10Ω
Red, Blue 170
±
10Ω
between Voltage
Gray, Orange 0.5V~4.5V
Yellow, Orange 5V
between Resistance
Red, Blue 100±10Ω
Red, White 130±10Ω